GE GSHL5KGXLS Use and Care Manual - Page 41
Performance Data Sheet, Operating Specifications
UPC - 084691171799
View all GE GSHL5KGXLS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
Performance Data Sheet SmartWater Filtration System GWF / HWF Cartridge This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors built in for unmetered usage) Parameter Chlorine T & O Particulate** USEPA MCL - - - Standard No. 42: Aesthetic Effects Influent Challenge Concentration Effluent Average Maximum 2.0 mg/L + 10% 0.02 ppm 0.05 ppm - - - at least 10,000 particles/mL 3,978 7,800 % Reduction Average Minimum 98.90% 97.37% - - 98.00% 96.10% Min. Required Reduction > 50% - > 85% Parameter Turbidity Cysts Lead at pH 6.5 Lead at pH 8.5 Lindane Atrazine 2,4-D Asbestos USEPA MCL 1 NTU*** 99.95% Reduction 15 ppb 15 ppb 0.0002 ppm 0.003 ppm 0.100 ppm 99% Standard No. 53: Health Effects Influent Challenge Concentration Effluent Average Maximum 11 + 1 NTU*** 0.07 NTU 0.1 NTU Minimum 50,000 L 26 55 0.15 mg/L + 10% 1 ppb 1 ppb 0.15 mg/L + 10% 1.8 ppb 4.3 ppb 0.002 mg/L + 10% 0.00005 ppm 0.00005 ppm 0.009 mg/L + 10% 0.002 ppm 0.003 ppm 0.210 mg/L + 10% 0.042 ppm 0.090 ppm 107 to 108 fibers/L; fibers greater than 10 micrometers in length 0.32 MFL/ml 1.2 MFL/ml % Reduction Average Minimum 99.71% 99.59% 99.97% 99.95% 99.37% 99.37% 98.8% 97.13% 91.93% 91.93% 76.19% 64.28% 84.89% 67.63% 99.95% 99.82% Min. Required Reduction 0.5 NTU > 99.95% 0.010 mg/L 0.010 mg/L 0.0002 mg/L 0.003 mg/L 0.07 mg/L 99% * Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C ** Measurement in Particles/ml. Particles used were 0.5-1 microns *** NTU=Nephelometric Turbidity units Operating Specifications Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light; up to one year for models with a replacement filter indicator light Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock Temperature: 33-100ºF (0.6-38ºC) Flow rate: 0.5 gpm (1.9 lpm) General Installation/Operation/Maintenance Requirements Flush new cartridge at full flow for 3 minutes to purge out trapped air. Replace cartridge when flow becomes too slow. Special Notices Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter cartridges. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water. Check for compliance with the state and local laws and regulations. Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines. System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of: Standard No. 42: Aesthetic Effects Standard No. 53: Health Effects Chemical Unit Taste and Odor Reduction Chlorine Reduction Chemical Reduction Unit Lead and Atrazine Reduction Lindane and 2,4-D Reduction Mechanical Filtration Unit Particulate Reduction, Class I Mechanical Filtration Unit Turbidity Reduction Cyst and Asbestos Reduction NSF® Manufactured for: General Electric Company, Louisville, KY 40225 41