Exhaust Length

Page 9 highlights

Installation Instructions • DO cut duct as short as possible and install straight into wall. • DO use elbows when turns are necessary. Elbows • DO NOT bend or collapse ducting. Use elbows if turns are necessary. • DO NOT use excessive exhaust length. Cut duct as short as possible. • DO NOT crush duct against the wall. • DO NOT set dryer on duct. EXHAUST LENGTH Using exhaust longer than specified length will: • Increase the drying times and the energy cost. • Reduce the dryer life. • Accumulate lint, creating a potential fire hazard. The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered by the warranty. EXHAUST LENGTH FOR NORMAL VENT MODELS RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct, number of turns, the type of exhaust hood (wall cap) and all conditions noted on the chart. • Internal elbows added for side or bottom vent conversions must be included in the total elbow count. • Any elbow greater than 45° should be treated as a 90° elbow. • Two 45° elbows will be treated like one 90° elbow. • For every additional 90° elbow, reduce the allowable vent system length by 10 feet. • When calculating the total vent system length, you must add all the straight portions and elbows of the system (including the transition duct). EXHAUST LENGTH FOR LONG VENT MODELS RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. No. of 90° Elbows 0 1 2 3 4 4" Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 2-1/2" Rigid Metal 60 Feet 45 Feet 35 Feet 25 Feet 15 Feet No. of 90° Elbows 0 1 2 3 4 5 9 4" Rigid Metal 150 Feet 135 Feet 125 Feet 115 Feet 105 Feet 95 Feet 2-1/2" Rigid Metal 125 Feet 115 Feet 105 Feet 95 Feet 85 Feet 75 Feet

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Installation Instructions
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire
hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not
covered by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust
system depends upon the type of duct, number of
turns, the type of exhaust hood (wall cap) and all
conditions noted on the chart.
Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
Any elbow greater than 45° should be treated as a
90° elbow.
Two 45° elbows will be treated like one 90° elbow.
For every additional 90° elbow, reduce the allowable
vent system length by 10 feet.
When calculating the total vent system length, you
must add all the straight portions and elbows of the
system (including the transition duct).
EXHAUST LENGTH
9
DO NOT
bend
or collapse
ducting. Use
elbows if turns
are necessary.
DO NOT
use
excessive
exhaust
length. Cut
duct as short
as possible.
DO NOT
crush duct
against the
wall
.
DO NOT
set dryer
on duct
.
DO
cut duct as short
as possible and install
straight into wall.
DO
use elbows when
turns are necessary.
Elbows
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows
Rigid
Metal
Rigid
Metal
150 Feet
135 Feet
125 Feet
115 Feet
105 Feet
125 Feet
115 Feet
105 Feet
0
1
2
3
4
Use only for short
run installations
5
EXHAUST LENGTH
FOR LONG VENT MODELS
95 Feet
95 Feet
85 Feet
75 Feet
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows
Rigid
Metal
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
0
1
2
3
4
Use only for short
run installations
EXHAUST LENGTH
FOR NORMAL VENT MODELS