GE GTUP240EMWW Quick Specs - Page 2

Unitized Spacemaker, Washer and Dryer - installation

Page 2 highlights

4" DIA. 4" DIA. 4" 2-1/2" GTUP240EM/240GM No. of 90º Elbows Rigid Metal Rigid Metal GE®01 24" Unitiz54e66 FFdeeeettSpacemake4326rFF®eeeeWtt asher and Dryer 2 34 Feet 28 Feet Dime3nsions and Installa32tioFneeItnformation (in inche1s8) Feet For complete information, see installation instructions packed with your dryer. Ducting Materials: GTUP240EM/GM DRYER EXHAUST LENGTH This dryer MUST be vented with 4" diameter all rigid metal exhaust duct. RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. Exhaust Length Calculation: 1. D etermine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2. T he maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. 4" DIA. 4" DIA. Dryers must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint 4" 2-1/2" and grease could create a fire hazard. No. of 90º Elbows 0 1 2 6 Rigid Metal 43 Feet 33 Feet 24 Feet Rigid Metal 36 Feet 26 Feet 16 Feet Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52." • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces 0" both sides 3" rear Listed by Underwriters Laboratories Specification Revised 2/11 360329

  • 1
  • 2
  • 3

Dimensions and Installation Information (in inches)
360329
GTUP240EM/240GM
GE
®
24" Unitized Spacemaker
®
Washer and Dryer
Listed by
Underwriters
Laboratories
Specification Revised 2/11
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
This dryer MUST be vented with 4" diameter all rigid metal exhaust duct.
Exhaust Length Calculation:
1.
Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2.
The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown
in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn
over 45° should be treated as a 90° elbow.
Dryers
must
be exhausted to the outside.
Caution:
For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52
"
.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" both sides
3" rear
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at ge.com
or call GE Answer Center
®
service, 800.626.2000.
GTUP240EM/GM DRYER EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
43 Feet
33 Feet
24 Feet
0
1
2
36 Feet
26 Feet
16 Feet
Use only for short
run installations