GE GTUP270EMWW Quick Specs - Page 2

Unitized Spacemaker, Washer and Dryer

Page 2 highlights

GTUP270EM/270GM GE® 27" Unitized Spacemaker® Washer and Dryer Dimensions and Installation Information (in inches) GTUP270EM/GM DRYER EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. No. of 90º Elbows 0 1 2 3 4" Rigid Metal 56 Feet 46 Feet 34 Feet 32 Feet 2-1/2" Rigid Metal 42 Feet 36 Feet 28 Feet 18 Feet GTUP240EM/GM DRYER EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. 4" 2-1/2" No. of 90º Rigid Rigid Elbows Metal Metal For an0swers to your Mon4o3gFreaemt ,® GE Profile™ or 36 Feet GE® a1ppliance questions3,3viFsieteotur website at ge.com26 Feet or cal2l GE Answer Center2®4sFeerevtice, 800.626.2000. 16 Feet 6 For complete information, see installation instructions packed with your dryer. Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ­ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length of the transition duct. Please see installation instruction packed with your dryer for complete instructions when using flexible metal (foil type) ducting. Exhaust Length Calculation: 1. D etermine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2. T he maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. Dryers must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side and rear 1" front and top • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52." • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces 0" either side and rear 1" front and top Listed by Underwriters Laboratories Specification Revised 2/11 360328

  • 1
  • 2
  • 3

Dimensions and Installation Information (in inches)
360328
GTUP270EM/270GM
GE
®
27" Unitized Spacemaker
®
Washer and Dryer
Listed by
Underwriters
Laboratories
Specification Revised 2/11
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal
duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special
installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal
(semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer for complete instructions when
using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1.
Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2.
The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown
in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn
over 45° should be treated as a 90° elbow.
Dryers
must
be exhausted to the outside.
Caution:
For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52
"
.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at ge.com
or call GE Answer Center
®
service, 800.626.2000.
GTUP270EM/GM DRYER EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
56 Feet
46 Feet
34 Feet
32 Feet
0
1
2
3
42 Feet
36 Feet
28 Feet
18 Feet
Use only for short
run installations