GTX22EASK GE Appliances Series 6.2 Cu. Ft. Capacity Aluminized Alloy Drum Electric Dryer 22 1/2" 26 3/4" DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) 27" POWER CORD 4 1/2" 11 3/4" ELECTRIC DRYER RATING: 240V 5600W 24A 60Hz 208V 4400W 22A 60Hz EXHAUST OPTION: 4-way rear, right, left and bottom CIRCUIT REQUIREMENTS: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required. NOTE: Dryer wall outlet must be located within 36" of service cord entry and acessible when dryer is mounted in position. INSTALLATION INFORMATION: For complete information, see installation instructions packed with your dryer. 44" 37 1/2" 4 1/4" 1 3/4" 4" 3 1/4" 5" SIDE VIEW REAR VIEW SPECIAL INSTALLATION REQUIREMENTS ALCOVE OR CLOSET INSTALLATION: - I f your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. - T he dryer MUST be exhausted to the outside. - M inimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 1" front, top and rear - C loset doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. - N o other fuel-burning appliance shall be installed in the same closet with a gas dryer. BATHROOM OR BEDROOM INSTALLATION: - T he dryer MUST be exhausted to the outdoors. - T he installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers. MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION: - M inimum clearances to combustible surfaces are: 0" both sides; 1" rear DRYER EXHAUSTING INFORMATION­: Use metal duct only, vertical and horizontal ducting. Listed by Underwriters Laboratories For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000. Specification Revised 5/16

  • 1
  • 2
  • 3

Listed by
Underwriters
Laboratories
GTX22EASK
GE
Appliances Series 6.2 Cu. Ft. Capacity Aluminized
Alloy Drum Electric Dryer
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 5/16
ELECTRIC DRYER RATING:
240V
5600W
24A
60Hz
208V
4400W
22A
60Hz
EXHAUST OPTION:
4-way rear, right,
left and bottom
CIRCUIT REQUIREMENTS:
An
individual, properly-grounded branch
circuit, protected by a 30-amp circuit
breaker or a time-delay fuse, is required.
NOTE:
Dryer wall outlet must be
located within 36" of service cord entry
and acessible when dryer is mounted in
position.
INSTALLATION INFORMATION:
For complete information, see installation
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on
the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.
of open area equally distributed. If this closet contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION:
Use metal duct only, vertical and horizontal ducting.
22 1/2"
26 3/4"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
POWER CORD 4 1/2"
11 3/4"
SIDE VIEW
REAR VIEW