GTX33GASK GE Appliances 6.2 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer 22 1/2" 26 3/4" 27" POWER CORD 4 1/2" 11 3/4" DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) EXHAUST OPTION: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied. GAS: An individual, properly-grounded branch circuit, with a three-prong groundingtype receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required. GAS DRYER ELECTRIC RATING: 120V, 60Hz, 6A GAS (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation. NOTE: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position. INSTALLATION INFORMATION: For complete information, see installation instructions packed with your dryer. SIDE VIEW 44" 37 1/2" 4 1/4" 4" 1 3/4" 3 1/4" 5" REAR VIEW SPECIAL INSTALLATION REQUIREMENTS ALCOVE OR CLOSET INSTALLATION: - I f your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. - T he dryer MUST be exhausted to the outside. - M inimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 1" front, top and rear - C loset doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. - N o other fuel-burning appliance shall be installed in the same closet with a gas dryer. BATHROOM OR BEDROOM INSTALLATION: - T he dryer MUST be exhausted to the outdoors. - T he installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers. MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION: - M inimum clearances to combustible surfaces are: 0" both sides; 1" rear DRYER EXHAUSTING INFORMATION­: Use metal duct only, vertical and horizontal ducting. For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000. Specification Revised 5/16

  • 1
  • 2
  • 3

GTX33GASK
GE
Appliances
6.2 Cu. Ft. Capacity Aluminized
Alloy Drum Gas Dryer
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 5/16
EXHAUST OPTION:
When viewed from the
front of the unit, exhaust 3-way via rear, left
and bottom. Dryer is shipped exhausted to
the rear. Alternate exhausting knockouts are
supplied.
GAS:
An individual, properly-grounded
branch circuit, with a three-prong grounding-
type receptacle, protected by a 15 or 20 amp
circuit breaker or a time-delay fuse is required.
GAS DRYER ELECTRIC RATING:
120V, 60Hz, 6A
GAS (BTU/HR):
22,000. Factory-equipped
for natural gas. Tested for LP gas. LP gas
supply requires a conversion kit. Check
installation instructions for correct kit and
have a qualified gas technician install a
conversion kit. See dryer ducting information
for proper installation.
NOTE:
Dryer wall outlet must be located
within 36" of service cord entry and accessible
when dryer is mounted in position.
INSTALLATION INFORMATION:
For complete information, see installation
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
22 1/2"
26 3/4"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
POWER CORD 4 1/2"
11 3/4"
SIDE VIEW
REAR VIEW
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on
the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.
of open area equally distributed. If this closet contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION:
Use metal duct only, vertical and horizontal ducting.