Installation Instructions Range Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com IN THE COMMONWEALTH OF MASSACHUSETTS „ This product must be installed by a licensed plumber or gas fitter. „ When using ball type gas shut-off valves, they shall be the T-handle type. „ A flexible gas connector, when used, must not exceed 3 feet. WARNING FIRE OR EXPLOSION HAZARD If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Installation must be performed by a qualified installer. Read these instructions completely and carefully. Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/ CGA-1.1 latest edition. When installing a gas appliance the use of old flexible connectors can cause gas leaks and personal injury. Always use a NEW flexible connector. Leak testing of the appliance shall be conducted according to the manufacturer instructions. The range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section. Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard. FOR YOUR SAFETY: WARNING Tip-Over Hazard • A child or adult can tip the range and be killed. • Install the anti-tip bracket to the wall or floor. • Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged. • Re-engage the anti-tip bracket if the range is moved. • Failure to do so can result in death or serious burns to children or adults. If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost. (In Canada, call 1.800.561.3344.) For installation instructions of the bracket, visit: www.GEAppliances.com. (In Canada, www.GEAppliances.ca.) Anti-Tip Bracket Kit Included WARNING Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. TOOLS YOU WILL NEED Phillips screwdriver Flat-blade screwdriver Pencil and ruler Open-end or adjustable wrench Level Pipe wrenches (2) (one for backup) Drill, awl or nail MATERIALS YOU MAY NEED „ Gas line shut-off valve „ Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and LP gases „ Flexible metal appliance connector (1/2" I.D.). A 5-foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new range. „ Flare union adapter for connection to gas supply line (3/4" or 1/2" NPT x 1/2" I.D.) „ rFelagruelautnoiroonnardaanpgteer(1fo/2r"cNonPnTexct1io/2n"tIo.Dp.)ressure „ Liquid leak detector or soapy water. *Teflon: Registered trademark of DuPont BEFORE YOU BEGIN ,03257$17³ Save these instructions for local inspector's use. ,03257$17³ Observe all governing codes and ordinances. ,03257$17³ Remove all packing material and literature from oven before connecting gas and electrical supply to range. ,03257$17³ To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C). Note to Installer - Be sure to leave these instructions with consumer. Note to consumer - Keep these instructions for future reference. Servicer - The electrical diagram is in an envelope attached to the back of the range. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under warranty. Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4" thick plywood or similar insulator is placed between the range and carpeting. Mobile Home - Additional Installation Requirements The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/ NFPA 501A or with local codes. In Canada, the installation of this range must conform with the current standards CAN/CSAA240-latest edition, or with local codes. When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above. DIMENSIONS AND CLEARANCES Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range. Allow 30" (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4" (6.4 mm) thick flame-retardant millboard covered with no less than No. 28 MSG sheet metal (.015" [.38 mm] thick), .015" (.38 mm) thick stainless steel, .025" (0.64 mm) aluminum or .020" (0.5 mm) copper. Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance. For island installation, maintain 2-1/2" minimum from cutout to back edge of countertop and 3" minimum from cutout to side edges of countertop. 11 1/4" 36 1/4" ± 1/4 27 3/4" w/o handle 29 1/2" w/ handle 30" 47 5/8" Minimum to cabinets on either side of the range 3" 18" Minimum clearance to left wall 30" 30" Minimum To cabinets below cooktop and at the 0" range back Maximum depth for cabinets above countertops 6" Minimum clearance to right wall 1/4" 13" Front edge of the range side panel forward from cabinet 0" To cabinets below cooktop and at the range back DIMENSIONS AND CLEARANCES (CONT.) GAS PIPE AND ELECTRICAL OUTLET LOCATIONS Recommended area for 120V outlet on rear wall and area for through-the-wall connection of pipe stub and shut-off valve. Recommended area for through-the-floor connection of pipe stub and shut-off valve. CAUTION To prevent drafts from affecting burner operation, seal all openings in floor under appliance and behind appliance wall. CONVERTING TO LP GAS (OR CONVERTING BACK TO NATURAL GAS FROM LP) This range leaves the factory set for use with natural gas. If you want to convert to LP gas, the conversion must be performed by a qualified LP gas installer. The conversion orifices and instructions can be found on back of the range. Keep these instructions and all orifices in case you want to convert back to natural gas. Orifice Box (location may vary) Rear of Range 1 GAS SUPPLY WARNING Fire Hazard: Do not use a flame to check for gas leaks. WARNING Explosion Hazard: Do not exceed 25 ft-lbs of torque when making gas line connections. Overtightening may crack the pressure regulator resulting in fire or explosion hazard. Gas Pressure Regulator You must use the gas pressure regulator supplied with this range. For proper operations the inlet pressure to the regulator should be as follows: Natural Gas: Minimum pressure: 6" of Water Column Maximum pressure: 13" of Water Column LP Gas: Minimum pressure: 11" of Water Column Maximum pressure: 13" of Water Column If you are not sure about the inlet pressure contact local gas supplier. Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don't forget to relight the pilot on other gas appliances when you turn the gas back on. Because hard piping restricts movement of the range, the use of a CSA Internationalcertified flexible metal appliance connector is recommended unless local codes require a hardpiped connection. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made. To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads. A. Install a manual shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range. B. Install male 1/2" flare union adapter to the 1/2" NPT internal thread at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage. C. Install male 1/2" or 3/4" flare union adapter to the NPT internal thread of the manual shut-off valve, taking care to back-up the shut-off valve to keep it from turning. D. Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve. E. When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system. When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using pressures of 1/2 psig or less to pressure test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve. When checking for proper operation of the regulator, the inlet pressure must be at least 1" greater than the operating (manifold) pressure as given on rating label of product. *Teflon: Registered trademark of DuPont CONNECTOR HOOKUP Pressure regulator Flexible Option Gas Flow into Range Adapter 1/2" or 3/4" Gas pipe Flex connector (6 ft. max.) Adapter Gas shut-off valve Elbow Gas Flow into Range Elbow Nipple Pressure regulator Rigid Pipe Option Union Nipple Gas shut-off valve 1/2" or 3/4" Gas pipe Installer: Inform the consumer of the location of the gas shut-off valve. 31-10888 05-13 GE 2 ELECTRICAL CONNECTIONS WARNING Shock Hazard: This appliance must be properly grounded. Failure to do so can result in electric shock. Electrical Requirements - 120-volt, 60 Hertz, properly grounded dedicated circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse. Note: Use of automatic, wireless, or wired external switches that shut off power to the appliance are not recommended for this product. Grounding The power cord of this appliance is equipped with a three-prong (grounding) plug which plugs into a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded. Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle. DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN ADAPTER. DO NOT USE AN EXTENSION CORD. Ground Fault Circuit Interrupters (GFCI's) are not required or recommended for gas range receptacles. Performance of the range will not be affected if operated on a GFCI-protected circuit but occasional nuisance tripping of the GFCI breaker is possible. Ensure proper ground exists before use 3 SURFACE BURNERS Cap WARNING Fire or Explosion Hazard: Do not operate the burner without all burner parts in place. Burner Make sure the notch in the burner head is positioned over the electrode. A. Burners - Place surface burners into corresponding positions on cooktop. B. Caps - Place caps on proper size burner.. C. Continuous Grates - Place the left and right grates on the cooktop. These grates are marked "LEFT" and "RIGHT" on their undersides. Place the center grate with its short edge toward the front of the range. Cap Hole or Notch Electrode Electrode Front right burner Left Center Right 4 CHECK SURFACE BURNERS Push and turn knob to LITE position. You will hear a clicking sound indicating proper operation of the spark module. Once the air has been purged from the supply lines, burners should light within 4 seconds. After burner lights, rotate knob out of the LITE position. Try each burner in succession until all burners have been checked. Quality of Flames The flame quality of the burners needs to be determined visually. If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use With LP gas, some yellow tipping on outer cones is normal. $ 

  • 1

CONVERTING TO LP GAS
(OR CONVERTING BACK TO
NATURAL GAS FROM LP)
This range leaves the factory set for use with
natural gas. If you want to convert to LP
gas, the conversion must be performed by a
qualified LP gas installer.
The conversion orifices and instructions can be
found on back of the range.
Keep these instructions and all orifices in case
you want to convert back to natural gas.
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the
range and adjacent combustible surfaces. These
dimensions must be met for safe use of your
range.
Allow 30” (76.2 cm) minimum clearance between
burners and bottom of unprotected wood or
metal cabinet, or allow a 24” (61 cm) minimum
when bottom of wood or metal cabinet is
protected by no less than 1/4” (6.4 mm) thick
flame-retardant millboard covered with no less
than No. 28 MSG sheet metal (.015” [.38 mm]
thick), .015” (.38 mm) thick stainless steel, .025”
(0.64 mm) aluminum or .020” (0.5 mm) copper.
Installation of a listed microwave oven or
cooking appliance over the cooktop shall
conform to the installation instructions packed
with that appliance.
For island installation, maintain 2-1/2” minimum
from cutout to back edge of countertop and
3” minimum from cutout to side edges of
countertop.
CONNECTOR HOOKUP
TOOLS YOU WILL NEED
MATERIALS YOU MAY NEED
Gas line shut-off valve
Pipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural
and LP gases
Flexible metal appliance connector (1/2
I.D.).
A 5-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a
new range.
Flare union adapter for connection to gas
supply line (3/4
or 1/2
NPT x 1/2
I.D.)
Flare union adapter for connection to pressure
regulator on range (1/2
NPT x 1/2
I.D.)
Liquid leak detector or soapy water.
*Teflon: Registered trademark of DuPont
31-10888
05-13
GE
Flat-blade
screwdriver
Pipe wrenches (2)
(one for backup)
Phillips
screwdriver
Open-end or
adjustable wrench
Pencil and ruler
Level
Drill, awl or nail
To cabinets
below cooktop
and at the
range back
Minimum to
cabinets on
either side
of the range
30”
30”
Minimum
13”
6”
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge
of the range
side panel
forward from
cabinet
0”
To cabinets
below cooktop
and at the
range back
1/4”
3”
Minimum
clearance
to left wall
0”
Rear of Range
Orifice Box
(location
may vary)
Pressure
regulator
Gas Flow into Range
Gas Flow into Range
Flex
connector
(6 ft. max.)
Adapter
Installer: Inform the consumer of the location of the gas shut-off valve.
1/2
or 3/4
Gas pipe
Adapter
Gas
shut-off
valve
Pressure
regulator
Elbow
Elbow
Nipple
Union
Nipple
Gas
shut-off
valve
1/2
or 3/4
Gas pipe
Flexible
Option
Rigid Pipe
Option
IN THE COMMONWEALTH OF
MASSACHUSETTS
This product must be installed by a licensed
plumber or gas fitter.
When using ball type gas shut-off valves, they
shall be the T-handle type.
A flexible gas connector, when used, must not
exceed 3 feet.
Installation Instructions
Range
Questions?
Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
BEFORE YOU BEGIN
Save these instructions for
local inspector’s use.
Observe all governing
codes and ordinances.
Remove all packing
material and literature from oven before
connecting gas and electrical supply to range.
To avoid damage to your
cabinets, check with your builder or cabinet
supplier to make sure that the materials used will
not discolor, delaminate or sustain other damage.
This oven has been designed in accordance with
the requirements of UL and CSA International
and complies with the maximum allowable wood
cabinet temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these
instructions with consumer.
Note to consumer – Keep these instructions for
future reference.
Servicer – The electrical diagram is in an
envelope attached to the back of the range.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under warranty.
Before installing your range on linoleum or any
other synthetic floor covering, make sure the
floor covering can withstand 180°F without
shrinking, warping or discoloring. Do not install
the range over carpeting unless a sheet of 1/4”
thick plywood or similar insulator is placed
between the range and carpeting.
Mobile Home - Additional Installation
Requirements
The installation of this range must conform to
the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction
and Saftey, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for
Manufactured Home Installations, ANSI A225.1/
NFPA 501A or with local codes.
In Canada, the installation of this range must
conform with the current standards CAN/CSA-
A240-latest edition, or with local codes.
When this range is installed in a mobile home, it
must be secured to the floor during transit. Any
method of securing the range is adequate as
long as it conforms to the standards listed above.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
Installation must be performed by a qualified
installer.
Read these instructions completely and carefully.
Installation of this range must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the current
Propane Installation Code, CAN/CGA-B149.2, and
with local codes where applicable. This range
has been design-certified by CSA International
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to CAN/
CGA-1.1 latest edition.
When installing a gas appliance the use of old
flexible connectors can cause gas leaks and
personal injury. Always use a
NEW
flexible
connector.
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The range must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian
Electrical Code Part 1 and/or local codes. See
Electrical Connections in this section.
Do not install this product with an air curtain
hood or other range hood that operates by
blowing air down on the cooktop.
This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.
Recommended area for
120V outlet on rear wall and
area for
through-the-wall
connection of pipe stub and
shut-off valve.
Recommended area
for
through-the-floor
connection of pipe stub
and shut-off valve.
1
GAS SUPPLY
WARNING
Fire Hazard: Do not use a
flame to check for gas leaks.
WARNING
Explosion Hazard: Do not
exceed 25 ft-lbs of torque when making gas
line connections. Overtightening may crack
the pressure regulator resulting in fire or
explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied
with this range. For proper operations the inlet
pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column
LP Gas:
Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure
contact local gas supplier.
Shut off the main gas supply valve before
disconnecting the old range and leave it off
until the new hook-up has been completed.
Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Because hard piping restricts movement of
the range, the use of a CSA International-
certified flexible metal appliance connector is
recommended unless local codes require a hard-
piped connection.
If the hard piping method is used, you must
carefully align the pipe; the range cannot be
moved after the connection is made.
To prevent gas leaks, put pipe joint compound on,
or wrap pipe thread tape with Teflon* around, all
male (external) pipe threads.
A.
Install a manual shut-off valve in the gas line
in an easily accessed location outside of the
range. Make sure everyone operating the
range knows where and how to shut off the
gas supply to the range.
B.
Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of regulator. Use a
backup wrench on the regulator fitting to avoid
damage.
C.
Install male 1/2” or 3/4” flare union adapter to
the NPT internal thread of the manual shut-off
valve, taking care to back-up the shut-off valve
to keep it from turning.
D.
Connect flexible metal appliance connector
to the adapter on the range. Position range to
permit connection at the shut-off valve.
E.
When all connections have been made, make
sure all range controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.
When using pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using pressures of 1/2 psig or less to pressure
test the gas supply system, simply isolate the
range from the gas supply system by closing the
individual shut-off valve.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1”
greater than the operating (manifold) pressure as
given on rating label of product.
*Teflon: Registered trademark of DuPont
2
ELECTRICAL CONNECTIONS
WARNING
Shock Hazard: This
appliance must be properly grounded. Failure to
do so can result in electric shock.
Electrical Requirements -
120-volt, 60 Hertz,
properly grounded dedicated circuit protected by a
15-amp or 20-amp circuit breaker or time delay fuse.
Note:
Use of automatic, wireless, or wired external
switches that shut off power to the appliance are
not recommended for this product.
Grounding
The power cord of this appliance is equipped with
a three-prong (grounding) plug which plugs into a
standard three-prong grounding wall receptacle
to minimize the possibility of electric shock hazard
from this appliance.
The customer should have the wall receptacle
and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD. DO NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are
not required or recommended for gas range
receptacles. Performance of the range will not be
affected if operated on a GFCI-protected circuit
but occasional nuisance tripping of the GFCI
breaker is possible.
4
CHECK SURFACE BURNERS
Push and turn knob to LITE position. You will hear
a
clicking
sound indicating proper operation of
the spark module. Once the air has been purged
from the supply lines, burners should light within
4 seconds. After burner lights, rotate knob out of
the LITE position. Try each burner in succession
until all burners have been checked.
Quality of Flames
The flame quality of the burners needs to be
determined visually.
If burner flames look like (A), call for service.
Normal burner flames should look like (B) or (C),
depending on the type of gas you use
With LP gas, some yellow tipping on outer cones
is normal.
5
CHECK BAKE AND BROIL
BURNERS
To remove the oven bottom:
A.
Remove the screws holding down rear of the
oven bottom.
B.
Grasp the oven bottom at rear slots on each
side.
C.
Lift the rear of the oven bottom and slide it
back until it clears the lip of the range frame
at the front. Then lift bottom up and out.
Set Bake function to 350°F. Burner should
light in 30 to 90 seconds.
Check Flame Quality.
Flames should have approximately 1” blue
cones.
Natural gas should burn with no yellow
flames.
LP gas flames have slight yellow tips
After warming up, the flame should not lift
off the burner.
Check broil burner using the same method as
the bake burner.
Normal for natural gas
(B) Yellow tips on
Normal for LP gas
Call for service
FOR YOUR SAFETY:
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
to children or adults.
Tip-Over Hazard
WARNING
WARNING
Before beginning
the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at no
cost. (In Canada, call 1.800.561.3344.) For installation
instructions of the bracket, visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)
Anti-Tip Bracket
Kit Included
18”
6
ADJUST BAKE AND BROIL
AIR SHUTTER IF NECESSARY
To adjust the flow of air to either burner, loosen
the Phillips head screw and rotate the shutter
as needed.
A.
If the flames are yellow, open shutter more
than the original setting.
B.
If the flames lift off the burner, close the air
shutter more than the original setting.
Check flames again and adjust further if
necessary. Replace oven bottom.
Loosen
Air
shutter
Air
shutter
Loosen
Oven bottom
Ensure proper
ground exists
before use
CAUTION
To prevent drafts
from affecting burner operation, seal
all openings in floor under appliance
and behind appliance wall.
Slots
Broil Burner
Bake Burner
47 5/8"
29 1/2"
w/ handle
27 3/4"
w/o handle
30"
36 1/4" ± 1/4
11 1/4"
3
SURFACE BURNERS
WARNING
Fire or Explosion Hazard:
Do not operate the burner without all burner
parts in place.
A.
Burners -
Place surface burners into
corresponding positions on cooktop.
B.
Caps -
Place caps on proper size burner..
C.
Continuous Grates -
Place the left and
right grates on the cooktop. These grates
are marked “LEFT” and “RIGHT” on their
undersides. Place the center grate with its
short edge toward the front of the range.
Left
Right
Center
or
Front right burner
Make sure the notch in the
burner head is positioned
over the electrode.
Electrode
Electrode
Hole
Notch
Cap
Burner
Cap
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
WHEN ALL HOOKUPS ARE
COMPLETED
Make sure all controls are left in the off position.
Make sure the flow of combustion and ventilation
air to the range is unobstructed.
Check that all packing materials and tape have
been removed. This will include tape on metal
panel under control knobs (if applicable), adhesive
tape, wire ties, cardboard and protective plastic.
Failure to remove these materials could result in
damage to the appliance once the appliance has
been turned on and surfaces have heated.
7
INSTALL AND CHECK
ANTI-TIP DEVICE
WARNING
Never completely remove the
leveling leg as the range will not be secured to
the anti-tip device properly.
Follow instructions supplied with ANTI-TIP bracket
8
LEVEL THE RANGE
WARNING
Never completely remove the
leveling leg as the range will not be secured to
the anti-tip device properly.
A.
Plug in the unit.
B.
Measure the height of your countertop at the
rear of the opening (X).
C.
Adjust two rear leveling legs so that the rear of
cooktop is at the same height as the counter (Y).
D.
Slide unit into place.
E.
Install oven shelves in the oven and position the
range where it will be installed.
F.
Check for levelness by placing a spirit level on
the level placed diagonally first in one direction
and then the other.
G.
Adjust front leveling legs until the range is level.
H.
Look under the unit and verify that the rear leg
is fully engaged with the anti-tip device.
If not,
remove the unit and adjust the height of the
rear leg so that it is properly engaged.
Anti-Tip Bracket
Kit Included
Spirit level
X
Y