GE JGP963SEKSS Installation Instructions - Page 6

Installation Instructions, INSTALLATION-GAS CONNECTIONS - lp

Page 6 highlights

Installation Instructions InstallATION-GAS CONNECTIONS 1 Provide Adequate Gas Supply This cooktop is designed to operate on natural gas at 4″ of water column manifold pressure and 7″ of water column (W.C.) supply pressure. It is shipped from the factory set for natural gas. The convertible pressure regulator supplied with the unit must be connected in series with the manifold of the cooktop and must remain in series with the supply line regardless of whether natural or L.P. gas is being used. FOR PROPER OPERATION, THE MAXIMUM INLET PRESSURE TO THE REGULATOR MUST BE NO MORE THAN 14″ OF WATER COLUMN PRESSURE. For checking the regulator, the inlet pressure must be at least 1″ W.C.. (or 3.4 KPA) greater than the regulator output setting. If the regulator is set for 4″ W.C. of water column pressure, the inlet pressure must be at least 5″ W.C. If the regulator is set for 10″ W.C., the inlet pressure must be at least 11″ W.C.. The gas supply line to the cooktop should be 1/2″ or 3/4″ pipe. 2 Install Regulator NEVER REUSE OLD CONNECTORS WHEN INSTALLING THIS COOKTOP. WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new flexible connectors when installing a gas appliance. Screw a section of pipe onto the inlet end of the pressure regulator and install the coupling. Pressure Regulator Coupling To reduce the likelihood of gas leaks, apply teflon tape or a thread compound approved for use with LP or Natural gases to all threaded connections. 3 Install Regulator onto burner box bottom Screw the regulator onto the burner box bottom pipe connection. Make sure the top of the regulator is facing towards the cabinet front, easily accessible through the cabinet doors. Pressure Regulator Coupling Shut-Off Valve Electrical Outlet 12″ Below Countertop 4 Complete connection with a coupling Complete the connection between the regulator pipe coupling and the shut-off valve. Pressure Regulator Coupling Shut-Off Valve Electrical Outlet 12″ Below Countertop 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

6
Installation Instructions
INSTALLATION—GAS CONNECTIONS
1
PROvIDE ADEqUATE
GAS SUPPLY
This cooktop is designed to operate on natural gas
at 4
of water column manifold pressure and 7
of
water column (W.C.) supply pressure. It is shipped
from the factory set for natural gas. The convertible
pressure regulator supplied with the unit must
be connected in series with the manifold of the
cooktop and must remain in series with the supply
line
regardless of whether natural or L.P. gas is
being used.
FOR PROPER OPERATION, THE MAXIMUM INLET
PRESSURE TO THE REGULATOR MUST BE NO MORE
THAN 14
OF WATER COLUMN PRESSURE. For
checking the regulator, the inlet pressure must
be at least 1
W.C.. (or 3.4 KPA) greater than the
regulator output setting. If the regulator is set for 4
W.C. of water column pressure, the inlet pressure
must be at least 5
W.C. If the regulator is set for
10
W.C., the inlet pressure must be at least 11
W.C.. The gas supply line to the cooktop should be
1/2
or 3/4
pipe.
2
INSTALL REGULATOR
NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
WARNING:
Never reuse old
flexible connectors. The use of old flexible
connectors can cause gas leaks and personal
injury. Always use new flexible connectors when
installing a gas appliance.
To reduce the likelihood of gas leaks, apply teflon
tape or a thread compound approved for use with
LP or Natural gases to all threaded connections.
Screw a section of pipe onto
the inlet end of the pressure
regulator and install the
coupling.
3
INSTALL REGULATOR ONTO
BURNER BOx BOTTOM
Screw the regulator
onto
the burner box
bottom pipe
connection.
Make sure the
top of the regulator
is
facing towards the
cabinet front, easily
accessible through
the cabinet doors.
4
COMPLETE CONNECTION WITH A
COUPLING
Complete the
connection between
the regulator pipe
coupling and
the shut-off valve.
Pressure
Regulator
Pressure
Regulator
Shut-Off
Valve
Coupling
Electrical
Outlet 12
Below
Countertop
Coupling
Pressure
Regulator
Shut-Off
Valve
Coupling
Electrical
Outlet 12
Below
Countertop