GE JKP90DPBB Quick Specs - Page 1

GE JKP90DPBB - 27 in. Double Microwave/Thermal Wall Oven Manual

Page 1 highlights

JKP90DP GE® 27" Built-In Double Microwave/Thermal Wall Oven 10 D tion E Dimensions and Installation Information (in inches) KW RaAting 240V 6.4 208V 4.8 BreakeCr Size 240V 30 Amps Allow 3/4" for overlap of oven over all edges of cutout CL 2 x 4 or equivalent runners 208V 30 Am2p" Xs 4" or B equiv. runners H Note: Cabinets installed adjacent to wall ovens must have an adhesion spGec of at least a 194°F temperature rating. Suitable bracing to support runners 18" over centerline of cabinet (must support 275 lbs.) Note: if marks, blemishes or the cutout opening is visible above the installed oven, it may be n2e1cessary to add wood sChoimndusitunder the runners and front trim (48-1/2" until the marksloonrg)openinFgs are covered. NCaobtein:eDtosoarA2nh1dllo"adwnfordarmlwceilneepiamrrsrouatomnrnuceodafedsja3c"efnrotm45d°oaonrdfa9c0e°.walls should be ptolaacdejadcteonat cvoorindeirnst,erference with the handle. drawers, walls, etc. Electric wall ovens are not approved for installation with a plug and receptacle. They must be hard wired in accordance with installation instructions. Cabinet 27" A - Cabinet width required 27" min. B - Minimum cabinet depth 23-5/8" C - Opening width 25" min. - 25-1/4" max D - Opening height 41-1/4" max E - Minimum cutout location from floor 22" Oven F - Overall depth* 23-5/8" G - Overall height with trim 43" - 43-7/8" Overall height without trim 42-1/8" H - Overall width 26-5/8" *Depth including door handle is approximately 26-7/10" min. to 26-8/10" max. Installation Information: Before installing, consult installation instructions packed with product for ­current dimensional data. Note: These ovens are not approved for stackable or side-by-side installations. 10 Recommended junction box locations. Locate junction box either 5" MIN. below cutout floor or 48" MIN. above cutout floor D Access from adjacent cabinet required Minimum cutout location E from floor For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. A Allow 3/4" for overlap of oven over all edges of cutout C 2" X 4" or B equiv. runners H G 21 Conduit (48-1/2" long) F Allow minimum of 21" for clearance to adjacent corners, drawers, walls, etc. S b to s ru Cabin A - B - C - D - E - Oven F - G - H - *Dept 26-8/1 All GE ranges are equipped with an Anti-Tip device. The installation of this device is an important, required step in the installation of the range. Specification Created 5/09 Listed by Underwriters Laboratories 320357

  • 1
  • 2

Dimensions and Installation Information (in inches)
Listed by
Underwriters
Laboratories
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Specification Created 5/09
320357
JKP90DP
GE
®
27" Built-In Double Microwave/Thermal Wall Oven
KW Rating
240V
6.4
208V
4.8
Breaker Size
240V
30 Amps
208V
30 Amps
E
Minimum
cutout location
from floor
Allow minimum of
21" for clearance
to adjacent corners,
drawers, walls, etc.
21
2" X 4" or
equiv. runners
Conduit
(48-1/2"
long)
Allow 3/4" for overlap
of oven over all
edges of cutout
10
A
D
Recommended
junction box
locations.
Locate junction
box either 5" MIN.
below cutout
floor or 48" MIN.
above cutout
floor
C
B
F
G
H
Access
from
adjacent
cabinet
required
Note:
Cabinets installed adjacent to wall ovens
must have an adhesion spec of
at least a 194°F
temperature rating.
Note:
if marks, blemishes or the cutout opening is
visible above the installed oven, it may be necessary
to add wood shims under the runners and front trim
until the marks or openings are covered.
Note:
Door handle protrudes 3" from door face.
Cabinets and drawers on adjacent 45° and 90° walls
should be placed to avoid interference with the handle.
Electric wall ovens are not approved for installation
with a plug and receptacle. They must be hard wired
in accordance with installation instructions
.
Installation Information:
Before installing, consult
installation instructions packed with product for
current dimensional data.
Note:
These ovens are not approved for stackable or
side-by-side installations.
Cabinet
27"
A – Cabinet width required
27" min.
B – Minimum cabinet depth
23-5/8"
C – Opening width
25" min. - 25-1/4" max
D – Opening height
41-1/4" max
E – Minimum cutout location from floor
22"
Oven
F – Overall depth*
23-5/8"
G – Overall height with trim
43" - 43-7/8"
Overall height without trim
42-1/8"
H – Overall width
26-5/8"
*Depth including door handle is approximately 26-7/10" min. to
26-8/10" max.
C
L
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
18"
over centerline
of cabinet
(must support 275 lbs.)