JP3036DL/TL/SL GE Appliances 36" Built-In Knob Control Electric Cooktop DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) JP3036SL IMPORTANT: Requires a 5" free area between the bottom of the cooktop to any combustible material, i.e., shelving. Free area not required when installing wall oven underneath cooktop. Refer to installation instructions. Requires a 15" minimum from cooktop to adjacent overhead cabinets. Units are furnished with a 48" flexible armored cable. NOTE: 36" Ribbon cooktops are approved for use over select GE 30" Single Wall Ovens and Warming Drawers. Refer to cooktop and wall oven/warming drawer installation instructions packed with product for current dimensional data. If installed with a GE Telescopic Downdraft System, consult both the cooktop and downdraft installation instructions packed with product before installing. Cooktop gas/ electric supply may need to be re-routed to install downdraft. The countertop cutout requires 23-1/2" minimum flat countertop surface and 25" minimum total countertop depth. In addition, other clearances to front edge of the countertop must be considered. Before installing, consult installation instructions packed with product for ­ current dimensional data. APPROXIMATE COOKING DIMENSIONS 13" MAX. depth of unprotected overhead cabinets (when no hood or microwave is installed) 3-1/4" at front of unit and 5-9/16" at conduit location 36-1/8" 20-1/2" Cooktop 1-3/4" MIN. to rear wall 18-7/8" 33-3/4" 19-1/8" to 19-1/4" 33-7/8" to 34" 2-1/2" MIN. Required To insure accuracy, it is best to make a template when cutting the opening in the counter 30" MIN. from countertop to unprotected cabinet (when no hood or microwave is installed) See label next to nameplate for MIN. clearance to wall Electrical junction box 16" MIN. below countertop 2" MIN. clearance to side wall from cut-out on both sides of cooktop VOLTAGE (60HZ AC) CONNECTED LOAD (MAX.) CURRENT DRAW (MAX.) RECOMMENDED CIRCUIT BREAKER† 240V 9.0kW 37.5 Amps 40 Amps 208V 7.1kW 34.3 Amps 40 Amps †NOTE: Check local codes for required breaker size. 15" MIN. height from countertop to nearest cabinet (including light rails) on both sides of cooktop For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000. ADA COMPLIANT Listed by Underwriters Laboratories Specification Revised 1/17

  • 1
  • 2

JP3036DL/TL/SL
GE Appliances 36" Built-In Knob Control Electric Cooktop
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 1/17
To insure accuracy, it is best to make a
template when cutting the opening in the counter
Electrical junction box
16" MIN.
below countertop
Cooktop
36-1/8"
20-1/2"
18-7/8"
33-3/4"
19-1/8"
to
19-1/4"
33-7/8"
to
34"
2-1/2" MIN.
Required
1-3/4" MIN.
to rear wall
13" MAX.
depth of unprotected
overhead cabinets (when no
hood or microwave is installed)
15" MIN.
height from countertop
to nearest cabinet (including
light rails) on both sides of
cooktop
3-1/4"
at front of unit and
5-9/16"
at conduit location
30" MIN.
from countertop to
unprotected cabinet (when
no hood or microwave is
installed)
2" MIN.
clearance
to side wall from cut-out
on both sides of cooktop
See label next
to nameplate for
MIN. clearance
to wall
IMPORTANT:
Requires a 5" free area between
the bottom of the cooktop to any combustible
material, i.e., shelving. Free area not required
when installing wall oven underneath cooktop.
Refer to installation instructions. Requires
a 15" minimum from cooktop to adjacent
overhead cabinets. Units are furnished with a
48" flexible armored cable.
NOTE:
36" Ribbon cooktops are approved for
use over select GE 30" Single Wall Ovens and
Warming Drawers. Refer to cooktop and wall
oven/warming drawer installation instructions
packed with product for current dimensional
data. If installed with a GE Telescopic
Downdraft System, consult both the cooktop
and downdraft installation instructions packed
with product before installing. Cooktop gas/
electric supply may need to be re-routed to
install downdraft. The countertop cutout
requires 23-1/2" minimum flat countertop
surface and 25" minimum total countertop
depth. In addition, other clearances to front
edge of the countertop must be considered.
Before installing, consult installation
instructions packed with product for
current dimensional data
.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
APPROXIMATE COOKING DIMENSIONS
Listed by
Underwriters
Laboratories
ADA
COMPLIANT
VOLTAGE (60HZ AC)
240V
208V
CONNECTED LOAD (MAX.)
9.0kW
7.1kW
CURRENT DRAW (MAX.)
37.5 Amps
34.3 Amps
RECOMMENDED CIRCUIT BREAKER
40 Amps
40 Amps
NOTE:
Check local codes for required breaker size.