GE JV248PSS Use and Care Manual - Page 12
Run Wires, Cut Holes, Mark Holes
![]() |
UPC - 084691200475
View all GE JV248PSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Installation Instructions 11 MARK HOLES Select the vent option that your installation will require and proceed to that section: A. Outside top exhaust (Vertical duct-31⁄4″ x 10″ Rectangular) • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots. Hood mounting screws (4) 103⁄4″ (24″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) Cabinet front 103⁄4″ (24″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) 33⁄4″ 1⁄2″ 73⁄4″ Cabinet Bottom 51⁄4″ 51⁄4″ Vertical duct access hole 11⁄4″ 95⁄8″ 13⁄8″ Wood shims (recessed-bottom cabinets only-shims Electrical access hole Center (in cabinet bottom) line must be a minimum of 3/8″ thick and cut to fit the width of the inner recessed cabinet bottom) B. Outside top exhaust (Vertical duct-7″ Round) • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots. Hood mounting screws (4) 103⁄4″ (24″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) Cabinet front 103⁄4″ (24″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) Cabinet 73⁄4″ bottom Access 8″ DIA. HOLE 11⁄4″ 95⁄8″ hole for 7″ round duct 53⁄4″ 13⁄8″ Wood shims (recessed-bottom cabinets only-shims must be a Center minimum of 3/8″ thick and cut line to fit the width of the inner recessed cabinet bottom) Electrical access hole (in cabinet bottom) C. Outside rear exhaust (Horizontal duct-31⁄4″ x 10″ Rectangular) • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots. Wood shims (recessed-bottom cabinets only-shims must be a minimum of 3/8″ thick and cut to fit the width of the inner recessed cabinet bottom) Cabinet front 1⁄2″ 11⁄4″ 33⁄4″ Cabinet Horizontal duct access hole bottom 51⁄4″ 51⁄4″ 73⁄4″ 103⁄4″ (24″ hood) 103⁄4″ (24″ hood) 133⁄4″ (30″ hood) 133⁄4″ (30″ hood) 163⁄4″ (36″ hood) 163⁄4″ (36″ hood) Hood mounting screws (4) Center line Electrical access hole (in wall) D. Recirculating (non-vented ductless- JN327 and RN328, and optional on JV247, JV248, JV347, JV348 and JV367 models only) • Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots. • Since the hood is to be recirculated (not to be vented outside), do not cut out any vent openings in the wall or cabinet bottom. 12 CUT HOLES Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out 3/4″ extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease installation by cutting the hole 101⁄2″ instead of 10″. 13 RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes. NOTE: DO NOT turn the power on until installation is complete. 12
![](/manual_guide/products/general-electric-jv248pss-use-care-manual-c2e1595/12.png)