JVM3162RJ GE® 1.6 cu. ft. Over-the-Range Microwave Oven Dimensions and Installation Information (in inches) Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully. Exhaust Connection: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangularto-round transition adaptor must be used. Do not use less than a 6" diameter duct. Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust. Maximum Duct Length: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet. Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts. Duct A. Rectangular-To-round Transition Adaptor B. Wall Cap C. 90° Elbow D. 45° Elbow E. 90° Elbow F. 45° Elbow G. Roof Cap Equivalent Feet 5 ft. 40 ft. 10 ft. 5 ft. 25 ft. 5 ft. 24 ft. Optional Accessories (Available at additional cost) Filter Kit JX81C- Recirculating Charcoal Filter Kit To be used when the microwave oven cannot be vented to the outside. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. Listed by Underwriters Laboratories Specification Created 5/15

  • 1
  • 2
  • 3

Listed by
Underwriters
Laboratories
JVM3162RJ
GE
®
1.6 cu. ft. Over-the-Range Microwave Oven
Specification Created 5/15
For answers to your Monogram,
®
GE Profile
or GE
®
appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
HOOD EXHAUST DUCT:
Outside ventilation requires a
HOOD
EXHAUST DUCT
. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with
a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-
to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
120 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS
, etc., present additional
resistance to airflow and are equivalent to a section of straight duct which is
longer than their actual physical size. When calculating the total duct length,
add the equivalent length of all transitions and adaptors plus the lengths of all
straight duct sections. The chart below shows the approximate feet of equivalent
length of some typical ducts.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
DUCT
EQUIVALENT FEET
A.
Rectangular-To-round
Transition Adaptor
5 ft.
B.
Wall Cap
40 ft.
C.
90° Elbow
10 ft.
D.
45° Elbow
5 ft.
E.
90° Elbow
25 ft.
F.
45° Elbow
5 ft.
G.
Roof Cap
24 ft.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
FILTER KIT JX81C–
RECIRCULATING
CHARCOAL FILTER KIT
To be used when the
microwave oven cannot
be vented to the outside.