GE NX-1308E User Manual - Page 48

DESCRIPTION, DEFAULT, Segment #1, Segment #2, Segment #3, Segment #4

Page 48 highlights

LOC 84-87 88 89 90 91 92 93 94 95 96 97 98 PG DESCRIPTION DEFAULT DATA 32 RESERVED 0-0-0-0 RESERVED 32 PARTITION 1, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ 32 PARTITION 2, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ 32 PARTITION 2, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 1 Quick Arm 1 LED Extinguish enable 1 Open/Close 2 Re-Exit 2 Require user code for bypassing zones 2 Bypass 3 Auto Bypass 3 Bypass sounder alert 3 Restore 4 Silent Panic 4 AC Power/Low Battery sounder alert 4 Trouble 5 Audible Panic 5 Enables Bypass toggle 5 Tamper 6 Auxiliary 1 6 Enables Silent Auto Arm 6 Cancel 7 Auxiliary 2 7 Enables Automatic Instant 7 Recent Closing 8 Multi Keypress Tamper 8 Reserved 8 Exit Error 32 PARTITION 2 ENTRY/EXIT TIMERS Segment #1 (Entry Time #1) 0 _ Segment #2 (Exit Time #1) 0 _ Segment #3 (Entry Time #2) 0 _ Segment #4 (Exit Time #2) 0 _ 32 PARTITION 3, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ 33 PARTITION 3, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 1 Quick Arm 1 LED Extinguish enable 1 Open/Close 2 Re-Exit 2 Require user code for bypassing zones 2 Bypass 3 Auto Bypass 3 Bypass sounder alert 3 Restore 4 Silent Panic 4 AC Power/Low Battery sounder alert 4 Trouble 5 Audible Panic 5 Enables Bypass toggle 5 Tamper 6 Auxiliary 1 6 Enables Silent Auto Arm 6 Cancel 7 Auxiliary 2 7 Enables Automatic Instant 7 Recent Closing 8 Multi Keypress Tamper 8 Reserved 8 Exit Error 33 PARTITION 3 ENTRY/EXIT TIMERS Segment #1 (Entry Time #1) 0 _ Segment #2 (Exit Time #1) 0 _ Segment #3 (Entry Time #2) 0 _ Segment #4 (Exit Time #2) 0 _ 33 PARTITION 4, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ 33 PARTITION 4, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 1 Quick Arm 1 LED Extinguish enable 1 Open/Close 2 Re-Exit 2 Require user code for bypassing zones 2 Bypass 3 Auto Bypass 3 Bypass sounder alert 3 Restore 4 Silent Panic 4 AC Power/Low Battery sounder alert 4 Trouble 5 Audible Panic 5 Enables Bypass toggle 5 Tamper 6 Auxiliary 1 6 Enables Silent Auto Arm 6 Cancel 7 Auxiliary 2 7 Enables Automatic Instant 7 Recent Closing 8 Multi Keypress Tamper 8 Reserved 8 Exit Error 33 PARTITION 4, ENTRY/EXIT TIMERS Segment #1 (Entry Time #1) 0 _ Segment #2 (Exit Time #1) 0 _ Segment #3 (Entry Time #2) 0 _ Segment #4 (Exit Time #2) 0 _ 33 PARTITION 5, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ 48 NX-8 Control

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

NX-8 Control
48
LOC
PG
DESCRIPTION
DEFAULT
DATA
84-87
32
RESERVED
0-0-0-0
RESERVED
88
32
PARTITION 1, ACCOUNT CODE
10-10-10-10-10-10
_ _ _ _ _ _
89
32
PARTITION 2, ACCOUNT CODE
10-10-10-10-10-10
_ _ _ _ _ _
PARTITION 2, FEATURE AND REPORTING SELECTION
Segment #1
Segment #2
Segment #3
90
32
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
PARTITION 2 ENTRY/EXIT TIMERS
Segment #1
(Entry Time #1)
0
_
Segment #2
(Exit Time #1)
0
_
Segment #3
(Entry Time #2)
0
_
91
32
Segment #4
(Exit Time #2)
0
_
92
32
PARTITION 3, ACCOUNT CODE
10-10-10-10-10-10
_ _ _ _ _ _
PARTITION 3, FEATURE AND REPORTING SELECTION
Segment #1
Segment #2
Segment #3
93
33
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
PARTITION 3 ENTRY/EXIT TIMERS
Segment #1
(Entry Time #1)
0
_
Segment #2
(Exit Time #1)
0
_
Segment #3
(Entry Time #2)
0
_
94
33
Segment #4
(Exit Time #2)
0
_
95
33
PARTITION 4,
ACCOUNT CODE
10-10-10-10-10-10
_ _ _ _ _ _
PARTITION 4,
FEATURE AND REPORTING SELECTION
Segment #1
Segment #2
Segment #3
96
33
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
PARTITION 4, ENTRY/EXIT TIMERS
Segment #1
(Entry Time #1)
0
_
Segment #2
(Exit Time #1)
0
_
Segment #3
(Entry Time #2)
0
_
97
33
Segment #4
(Exit Time #2)
0
_
98
33
PARTITION 5, ACCOUNT CODE
10-10-10-10-10-10
_ _ _ _ _ _