GE PB930SHSS Quick Specs - Page 1

GE PB930SHSS Manual

Page 1 highlights

30" Free-Standing Electric Single Oven PB930SH GE Profile™ Series 30" Free-Standing Electric Convection Range with Warming Drawer Dimensions and Installation Information (in inches) Receptacle Locations Locally approved flexible service cord or conduit must be used because terminals are not accessible after range installation. See shaded area in drawing for location of electrical outlet box. Recommended outlet locations allow range to be installed directly against wall. Note: This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a 6" minimum spacing to surfaces less than 15" above the cooktop and adjacent cabinet is recommended to reduce exposure to steam, grease splatter and heat. Installation Information: Before installing, consult installation instructions for c­ urrent dimensional data and additional requirements. KW Rating 240V 13.5 208V 10.1 Breaker Size 240V 40 Amps† 208V 40 Amps† †Note: Check local codes for required breaker size. 30 2-1/2 Acceptable electrical outlet area 25 2-1/2 29-7/8 7 14-1/2 11 47 35-3/4 to 36-1/2 7-1/2 On models with warming drawers, electrical outlet must not be in this area. 25-1/2 w/o handle 28 w/handle 47-7/8 For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. All GE ranges are equipped with an Anti-Tip device. The installation of this device is an important, required step in the installation of the range. Specification Created 2/14 221043

  • 1
  • 2

All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Dimensions and Installation Information (in inches)
For answers to your Monogram
®
or GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
PB930SH
GE Profile
Series 30" Free-Standing Electric Convection Range
with Warming Drawer
Specification Created 2/14
221043
30
25
2-1/2
2-1/2
14-1/2
7-1/2
7
Acceptable electrical
outlet area
On models with warming drawers,
electrical outlet must not
be in this area.
29-7/8
47
11
35-3/4
to
36-1/2
w/o handle
w/handle
47-7/8
28
25-1/2
Receptacle Locations
Locally approved flexible service cord or conduit must be used
because terminals are not accessible after range installation.
See shaded area in drawing for location of electrical outlet box.
Recommended outlet locations allow range to be installed directly
against wall.
Note:
This appliance has been approved for 0” spacing to
adjacent surfaces above the cooktop. However, a 6” minimum
spacing to surfaces less than 15” above the cooktop and
adjacent cabinet is recommended to reduce exposure to
steam, grease splatter and heat.
Installation Information:
Before installing, consult installation
instructions for current dimensional data and additional
requirements.
KW Rating
240V
13.5
208V
10.1
Breaker Size
240V
40 Amps
208V
40 Amps
Note: