PGP9830SJ GE Profile™ Series 30" Downdraft Gas Cooktop Installing the Ductwork: Use galvanized or aluminum duct in 6" round or 3-1/4" x 10" size, or combination of both. PVC duct or locally approved piping should be used if installing under a poured concrete slab. Local building code must be followed in specifying type and schedule of all duct used. Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper. Laundry-type wall caps should never be used. For maximum efficiency use the shortest and straightest duct run possible, with as few fittings as possible. For satisfactory performance the duct run should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations. Through Cabinet Toe Space 10-1/8 Between Floor Joist 6-1/8 Venting Options Inside Wall to Roof Direct to Outside 9-1/8 18-3/4 Downward Venting For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. Rear Wall Venting Specification Revised 4/15

  • 1
  • 2
  • 3

PGP9830SJ
GE Profile
Series 30" Downdraft Gas Cooktop
Specification Revised 4/15
INSTALLING THE DUCTWORK:
Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of both.
PVC duct or locally approved piping should
be used if installing under a poured concrete
slab. Local building code must be followed in
specifying type and schedule of all duct used.
NOTE:
Ductwork must be vented to outside.
Do not vent into a wall, ceiling, crawlspace,
attic or any concealed space. Always
use an appropriate roof or wall cap with
damper.
Laundry-type wall caps should
never be used
. For maximum efficiency
use the shortest and straightest duct run
possible,
with as few fittings as possible. For
satisfactory
performance the duct run should
not exceed 100 feet equivalent length. Refer
to the table of equivalent lengths (shown in
installation instructions) for various duct
configurations.
REAR WALL VENTING
DOWNWARD VENTING
Through Cabinet Toe Space
Inside Wall to Roof
Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8