PHP900DM GE Profile™ 30" Electric Induction Cooktop Dimensions and Installation Information (in inches) KW Rating 240V 7.7 208V 5.8 Breaker Size 240V 40 Amps† 208V 40 Amps† †Note: Check local codes for required breaker size Important: Requires a 12" free area between the bottom of the cooktop to any combustible material, i.e., shelving. Free area not required when installing wall oven underneath cooktop. Refer to installation instructions. Requires a 15" minimum from cooktop to adjacent overhead cabinets. Units are furnished with a 36" flexible armored cable. Note: 36" Ribbon cooktops are approved for use over GE 30" Single Wall Ovens and Warming Drawers only. Refer to cooktop and wall oven/ warming drawer installation instructions packed with product for current dimensional data. If installed with a GE Profile™ Telescopic Downdraft System, consult both the cooktop and downdraft installation instructions packed with product before installing. Cooktop gas/electric supply may need to be re-routed to install downdraft. The countertop must be at least 26" deep with a flat surface area of 23-1/2" or more, front to back. In addition, other clearances to the front edge of the countertop must be considered, especially on raised bullnose countertops. Consult cabinet and countertop manufacturer's specs for flush mount installation prior to install. Installation Information: Before installing, consult installation instructions packed with product for current dimensional data. 29-3/4 21-3/8 Cooktop 3-1/4* 13" MAX. depth 28-1/2 19-5/8 30" MIN. to unprotected cabinet 1-3/4" to rear wall 15" MIN. to cabinet 2-1/2** Required *Depth of unit at conduit connection location (rear) is 6-1/4" on models PP980/975/950/945 and 4-5/8" on models PHP960/900, PP972/962/942/932/912 and JP6SS/356/346/340. **Raised bull nose countertops may require up to 3/8" additional clearance to prevent interference with curved front. 2" MIN. clearance to side wall from cut-out Electrical junction box 16" MIN. below countertop Above illustration intended for dimensional reference only. Refer to photograph for actual product appearance. 2" MIN. clearance to side wall from cut-out Cut should not interfere with cabinet structure at front For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Listed by Underwriters Laboratories Specification Revised 2/10 220580

  • 1
  • 2

For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
220580
Note:
Check local codes for required breaker size
Important:
Requires a 12" free area between
the bottom of the cooktop to any combustible
material, i.e., shelving. Free area not required
when installing wall oven underneath cooktop.
Refer to installation instructions. Requires a
15" minimum from cooktop to adjacent
overhead cabinets. Units are furnished with
a 36" flexible armored cable.
Note:
36" Ribbon cooktops are approved for use over GE 30" Single Wall
Ovens and Warming Drawers only. Refer to cooktop and wall oven/
warming drawer installation instructions packed with product for current
dimensional data. If installed with a GE Profile
Telescopic Downdraft System,
consult both the cooktop and downdraft installation instructions packed with
product before installing. Cooktop gas/electric supply may need to be
re-routed to install downdraft. The countertop must be at least 26" deep
with a flat surface area of 23-1/2" or more, front to back. In addition,
other clearances to the front edge of the countertop must be considered,
especially on raised bullnose countertops. Consult cabinet and countertop
manufacturer’s specs for flush mount installation prior to install.
Installation Information:
Before installing, consult installation instructions
packed with product for current dimensional data.
KW Rating
240V
7.7
208V
5.8
Breaker Size
240V
40 Amps
208V
40 Amps
Listed by
Underwriters
Laboratories
3-1/4*
Cooktop
2-1/2**
Required
28-1/2
19-5/8
29-3/4
21-3/8
*Depth of unit at conduit connection location (rear) is
6-1/4" on models PP980/975/950/945 and 4-5/8"
on models PHP960/900, PP972/962/942/932/912
and JP6SS/356/346/340.
**Raised bull nose countertops may require up to
3/8" additional clearance to prevent interference
with curved front.
Electrical junction box 16" MIN.
below countertop
30" MIN. to
unprotected
cabinet
Cut should
not interfere
with cabinet
structure
at front
2
"
MIN.
clearance to
side wall
from cut-out
2
"
MIN.
clearance to
side wall
from cut-out
1-3/4
"
to
rear wall
13" MAX.
depth
15" MIN.
to cabinet
PHP900DM
GE Profile
30" Electric Induction Cooktop
Dimensions and Installation Information (in inches)
Specification Revised 2/10
Above illustration intended for dimensional reference only.
Refer to photograph for actual product appearance.