GE PHP960SMSS Quick Specs - Page 1
GE PHP960SMSS - 36" Induction Cooktop Manual
UPC - 084691163688
View all GE PHP960SMSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
PHP960SM GE Profile™ 36" Electric Induction Cooktop Dimensions and Installation Information (in inches) KW Rating 240V 11.6 208V 8.7 Breaker Size 240V 50 Amps† 208V 50 Amps† †Note: Check local codes for required breaker size Important: Requires a 12" free area between the bottom of the cooktop to any combustible material, i.e., shelving. Free area not required when installing wall oven underneath cooktop. Refer to installation instructions. Requires a 15" minimum from cooktop to adjacent overhead cabinets. Units are furnished with a 36" flexible armored cable. Note: 36" Ribbon cooktops are approved for use over GE 30" Single Wall Ovens and Warming Drawers only. Refer to cooktop and wall oven/ warming drawer installation instructions packed with product for current dimensional data. If installed with a GE Profile™ Telescopic Downdraft System, consult both the cooktop and downdraft installation instructions packed with product before installing. Cooktop gas/electric supply may need to be re-routed to install downdraft. The countertop must be at least 26" deep with a flat surface area of 23-1/2" or more, front to back. In addition, other clearances to the front edge of the countertop must be considered, especially on raised bullnose countertops. Consult cabinet and countertop manufacturer's specs for flush mount installation prior to install. Installation Information: Before installing, consult installation instructions packed with product for current dimensional data. 36-1/8 21 Cooktop 3-1/4* 13" MAX. depth 33-7/8 19-1/8 30" MIN. to unprotected cabinet 1-3/4" to rear wall 15" MIN. to cabinet 2-1/2** Required *Depth of unit at conduit connection location (rear) is 6-1/2" on models PP980/975/950/945 and 4-5/8" on models PHP960/PP972/962/942/932/912, JP655/356/346. **Raised bull nose countertops may require up to 3/8" additional clearance to prevent interference with curved front. 2" MIN. clearance to side wall from cut-out Electrical junction box 16" MIN. below countertop 36_ss_cktp_install.eps 2" MIN. clearance to side wall from cut-out Cut should not interfere with cabinet structure at front For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Listed by Underwriters Laboratories Specification Revised 1/08 220578