Performance Data Sheet SmartWater Filtration System-GE® MSWF Cartridge This system has been tested and certified in filter model GE MSWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.* (Safety factors built in for unmetered usage.) Standard No. 42: Aesthetic effects Parameter USEPA MCL Influent Challenge Concentration Effluent Average Maximum Chlorine Taste & Odor - 2.0 mg/L ± 10% 0.06 mg/L 0.10 mg/L Particulate** - at least 10,000 particles/ 408,333 mL 670,000 Standard No. 53: Health effects Parameter USEPA MCL Influent Challenge Concentration Effluent Average Maximum Turbidity 1 NTU**** 11 ± 1 NTU**** 0.38 NTU 0.5 NTU Cysts*** 99.95% Reduction Minimum 50,000 L < 1 #/L 4 #/L Lead at pH 6.5 0.010 mg/L 0.15 mg/L ± 10% < 1 ppb < 1 ppb Lead at pH 8.5 0.010 mg/L 0.15 mg/L ± 10% 3.1 ppb 9.0 ppb Mercury at pH 6.5 0.002 mg/L 0.006 mg/L ± 10% 0.34 ppb 0.7 ppb Mercury at pH 8.5 0.002 mg/L 0.006 mg/L ± 10% 0.66 ppb 1.5 ppb Lindane 0.0002 mg/L 0.002 mg/L ± 10% < 0.02 ppb < 0.02 ppb Atrazine 0.003 mg/L 0.009 mg/L ± 10% < 0.5 ppb < 0.05 ppb 2, 4-D 0.070 mg/L 0.210 mg/L ± 10% 7.7 ppb 35 ppb Toxaphene 0.003 mg/L 0.015 mg/L ± 10% < 1 ppb < 1 ppb Benzene 0.005 mg/L 0.015 mg/L ± 10% < 0.5 ppb < 0.5 ppb Carbofuran 0.040 mg/L 0.080 mg/L ± 10% < 1 ppb 1 ppb P-Dichlorobenzene Asbestos 0.075 mg/L 99% Reduction 0.225 mg/L ± 10% 10 7 to 10 8 fibers/L; fibers > 10μm in length < 0.5 ppb < 0.17 MF/L < 0.5 ppb < 0.17 MF/L *Tested using pressure of 60 psig; pH of 7.5 ± 0.5; temp of 68º ± 5ºF (20º ± 2.5ºC). **Measurement in Particles/mL. Particles used were 0.5-1 microns. ***Based on the use of Cryptosporidium parvum oocysts. ****NTU=Nephelometric Turbidity Units Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSF testing. % Reduction Average Maximum 97% 9.1% 95.5% 89.4% Min. Required Reduction ≥ 50% ≥ 85% % Reduction Average Maximum 96.5% 95.4% > 99.99% > 99.99% 99.3% 99.3% 98.0% 95.5% 94.0% 89.6% 88.4% 73.7% > 99.0% > 99.0% > 93.9% > 94.3% 96.0% 82.0% > 92.9% > 92.9% > 96.8% > 97.0% > 98.7% > 98.7% > 99.7% > 99.8% > 99% > 99% Max. Permissible Product Water 0.5 NTU 99.95% 0.010 mg/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.0002 mg/L 0.003 mg/L 0.070 mg/L 0.003 mg/L 0.005 mg/L 0.040 mg/L 0.075 mg/L 99% Reduction Application Guidelines/Water Supply Parameters Service Flow Water Supply 0.9 gpm (3.14 lpm) Potable Water Water Pressure Water Temperature 40-120 psi (2.8-8.2 bar) 33ºF-100ºF (0.6ºC-38ºC) It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised. See insert for Warranty information. Operating Specifications • Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock • Temperature: 33-100°F (0.6-38°C) • Flow rate: 0.9 gpm (3.14 lpm) General Installation/Operation/Maintenance Requirements • Flush new cartridge at full flow for 4-1/2 gallons (about five minutes) to purge trapped air. • Replace cartridge when flow becomes too slow. • Protect from freezing by removing filter cartridge when temperatures are expected to drop below 40°F (4.4°C). Do not install systems in areas where ambient temperatures may go above 100ºF or below 40°F. Do not install on a hot water supply. Special Notices • Installation instructions are included with the product when shipped. • This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter cartridges. • Do not use with water that is microbiologically unsafe or of unknown quality with- out adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. • The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water. • Check for compliance with the applicable state and local laws and regulations. • Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines. • Installation and use MUST comply with all state and local plumbing codes. Do not install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi (552 kPa), you should install a pressure-limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. • Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition. • Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed. For conditions of use, health claims certified by the California Department of Public Health, and replacements, see performance data sheet. California Department of Public Health Certification #06-1834. The contaminants or other substances removed or reduced by this water filter are not necessarily in all users' water. Tested and Certified by NSF International against ANSI/NSF Standards 42 and 53 in model GE MSWF for the reduction of: Standard No. 42: Aesthetic Effects • Chemical - Chlorine Taste and Odor • Mechanical Filtration - Particulate Reduction, Class I GE Appliances Appliance Park Louisville, KY 40225 Standard No. 53: Health Effects • Chemical Reduction - Atrazine Reduction - Endrin Reduction - Benzene and Carbofuran Reduction - 1,4 Dichlorobenzene and 2,4-D Reduction geapplianceparts.com - Lead and Lindane Reduction - Mercury and Toxaphene Reduction • Mechanical Filtration - Cyst and Asbestos Reduction REPLACEMENT ELEMENT EPA #10350-MN-005 © 2010 General Electric Company PC61577C 43