PVM2070SM GE Profile™ Spacemaker® 2.0 Cu. Ft. Over-the-Range Microwave Oven Optional Accessories (Available at additional cost) Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully. Exhaust Connection: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct. Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust. Maximum Duct Length: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet. ELBOWS, TRANSITIONS, WALL AND ROOF CAPS: etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts. Filler Panel Kits JX40CT-Bisque JX41-Black JX40WH-White When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between ­ cabinets only; not for end-of-cabinet installation. Each kit ­contains two 3"-wide filler panels. Two kits are needed for a 42" opening. Filter Kits JX81H-Recirculating Charcoal Filter Kit To be used when the Spacemaker microwave oven cannot be vented to the outside. Decorative Panel Kits Duct Equivalent Feet A. Rectangular-To-round Transition Adaptor 5 ft. B. Wall Cap 40 ft. C. 90° Elbow 10 ft. D. 45° Elbow 5 ft. E. 90° Elbow 25 ft. F. 45° Elbow 5 ft. G. Roof Cap 24 ft. 3/8 depth JX22SS - Stainless Steel Decorative Panel Kit When replacing a Hi/Low range with a microwave/convection oven or Spacemaker over a range model, this panel kit fills in the area between the microwave and range left by the H-Low model. 30 19 Specification Created 7/07 Listed by Underwriters Laboratories 240271

  • 1
  • 2
  • 3

Listed by
Underwriters
Laboratories
Optional Accessories (Available at additional cost)
240271
Specification Created 7/07
Filler Panel Kits
JX40CT-Bisque
JX41–Black
JX40WH–White
When replacing a
36" or
42" range hood, this kit fills
in the additional width to
provide a custom built-in
appearance.
For installation between
cabinets only; not for
end-of-cabinet installation.
Each kit contains two
3"-wide filler panels. Two kits are
needed for a 42" opening.
Filter Kits
JX81H–Recirculating
Charcoal Filter Kit
To be used when
the Spacemaker
microwave oven
cannot be vented
to the outside
.
Duct
Equivalent Feet
A.
Rectangular-To-round
Transition Adaptor
5 ft.
B.
Wall Cap
40 ft
.
C
.
90° Elbow
10 ft.
D.
45° Elbow
5 ft.
E.
90° Elbow
25 ft
.
F.
45° Elbow
5 ft
.
G.
Roof Cap
24 ft
.
Hood Exhaust Duct:
Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust Connection:
The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round
transition adaptor must be used. Do not use less than a 6" diameter duct.
Rear Exhaust:
If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it
is constructed by leaving enough space between the wall studs to accommodate
exhaust.
Maximum Duct Length:
For satisfactory air movement, the total duct length of 3-1/4"
x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS:
etc., present additional resistance to
airflow and are equivalent to a section of straight duct which is longer than their
actual physical size. When calculating the total duct length, add the equivalent length
of all transitions and adaptors plus the lengths of all straight duct sections. The chart
below shows the approximate feet of equivalent length of some typical ducts.
PVM2070SM
GE Profile
Spacemaker
®
2.0 Cu. Ft. Over-the-Range Microwave Oven
19
30
3/8
depth
JX22SS - Stainless Steel Decorative Panel
Kit
When replacing a Hi/Low range with a
microwave/convection oven or Spacemaker
over a range model, this panel kit fills in the
area between the microwave and range left by
the H-Low model.