GE PVM9179SKSS Installation Instructions - Page 12
Vertical Duct, Installation Overview, Attach The Mounting Plate, To The Wall
View all GE PVM9179SKSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Installation Instructions A OUTSIDE TOP EXHAUST (Vertical Duct) INSTALLATION OVERVIEW A1. Attach Mounting Plate to Wall A2. Prepare Top Cabinet A3. Check Blower Motor Oientation A4. Adapt Blower for Outside Ventilation A5. Check Damper Operation A6. Mount Microwave Oven A7. Adjust Exhaust Adaptor A8. Connect Ductwork A1 ATTACH THE MOUNTING PLATE TO THE WALL A B To use toggle bolts: Mounting Plate Spacing for Toggles More Than Wall Thickness Toggle Wings Toggle Bolt C D Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud. Recommended locations on the mounting plate are indicated by A, B, C and D. 1 Remove the toggle wings from the bolts. 2 Insert the bolts into the mounting plate through the holes designated to go into drywall and reattach the toggle wings to 3ø4s onto each bolt. 12 Wall Bolt End 3 Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate. NOTE: Before tightening toggle bolts and wood screw, make sure the tabs on the mounting plate touch the bottom of the cabinet when pushed flush against the wall and that the plate is properly centered under the cabinet. CAUTION Be careful to avoid pinching fingers between the back of the mounting plate and the wall. 4 Tighten all bolts. Pull the plate away from the wall to help tighten the bolts.