GE WSLP1500JWW Quick Specs - Page 2
GE Spacemaker, Portable Washer
UPC - 084691183143
View all GE WSLP1500JWW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
prtbl_stnry_bifl_wshr_inst.eps WSLP1500J GE Spacemaker® Portable Washer Dimensions and Installation Information (in inches) WMK-35 Wall Kit Installation 2 x 4 24-1/2 6 20" Max. Opening 3 33-1/4 32 5-1/8 4" Dia. Exhaust Both Sides 3-1/8 5-1/8 8 3 120V 20A or 208-240V 30A 3-3/4 Rear Exhaust R.H EXH 79-1/4 DSKS433 DSKS333 78 74-1/8 38 2 x 4 WSLP1500 WSLS1500 Standpipe 33" Minimum If Less Than 33" Use Syphon Break Kit WH49X228 Service Cord Entry at Back of Appliances 46 Standpipe & Faucets 33" Min. 23-7/8 6 1-1/2 74-1/8 120V 15 or 20A 26 28 23-5/8 General Information: The back of the dryer is not accessible for service or maintenance after dryer mounting installation is complete. It is recommended that the dryer be checked and electrical installation completed prior to mounting. For service or maintenance requiring rear access, the dryer must be removed from the wall. caution: disconnect electrical current before installing or servicing dryer. The electrical outlet must be located above the dryer, or beside the dryer if adequate dryer-to-wall clearance is available. The outlet must be within three feet on a 240 volt dryer or a 120 volt dryer from the service cord entry on the rear of the dryer. Dryer Mounting Position These instructions explain two mounting positions for your 24 inch dryer. Installation Procedure: 1. Obtain two pieces of 2x4 long enough to span at least two wall studs and the width of the dryer. 2. Locate wall stud center lines. Mark wall stud center lines on two pieces of 2x4 in relationship to position dryer is to be mounted. 3. Referring to dimensional drawing, draw a horizontal reference line (72") from the floor to locate upper 2x4 support. 4. Position, level and secure upper 2x4 with four 1/4 x 3 inch wood screws. The bottom of the 2x4 should be positioned on reference line. 5. Referring to dimensional drawing, draw a horizontal reference line 32" down from the bottom of the upper 2x4 support. 6. Position, level and secure lower 2x4 with two 1/4 x 3 inch wood screws. The center line of the 2x4 should be positioned on reference line. 7. Referring to figure 1, mount the metal wall bracket 1/8 inch from the bottom of the upper 2x4 support with five 1-1/2 inch wood screws. 8. Referring to figure 2, remove one screw from each lower rear corner of dryer and, using same screws, secure lower brackets (supplied) as shown. 9. Dryer is supplied with exhaust at the top, locate and install outside exhaust duct referring to the dimensional drawing. For other optional exhaust directions as shown in dimensional drawing (rear and sides) refer to dryer installation instruction sheet. 10. Position the dryer on the wall mounting bracket and check that the dryer is plumbed. 11. If the dryer needs plumbing, use some of the twelve washers supplied with the kit as spacers behind lower brackets of figure 2 and secure the dryer to the lower 2x4 support using the remaining 1-1/2 inch wood screws. WALL BRACKET 2 x 4 1/8 " MAX figure 1 REAR VIEW Figure 1 FRONT VIEW This kit consists of the following: 1 Wall mounting bracket 2 Bottom Brackets 6-1/4 x 3 inch wood screws 7-1/4 x 1-1/2 inch wood screws 12 washers Dryer Requirements Carefully read and follow individual dryer installation instructions for exhausting requirements. figure 2 Figure 2 caution The 120 volt receptacle on the back of the 240 volt dryer must not be used with this wall mount kit. Listed by Underwriters Laboratories wall_bracket_lineart.eps Specification Revised 10/09 360429