Gigabyte GA-X99-Phoenix SLI User Manual - Page 50

rd System Fan/Pump Speed Control SYS_FAN3_PUMP Connector

Page 50 highlights

&& CPU OPT/Pump Fan Speed Control (CPU_OPT_PUMP Connector) Allows you to determine whether to enable the fan/pump speed control function and adjust the fan/pump speed. Normal Allows the fan/pump to run at different speeds according to the CPU temperature. You can adjust the fan/pump speed with System Information Viewer based on your system requirements. (Default) Silent Allows the fan/pump to run at slow speeds. Manual Allows you to control the fan speed in the curve graph. Full Speed Allows the fan/pump to run at full speeds. && CPU OPT/Pump Fan Control Mode Auto Lets the BIOS automatically detect the type of fan/pump installed and sets the optimal control mode. Voltage Voltage mode is recommended or a 3-pin fan/pump. (Default) PWM PWM mode is recommended or a 4-pin fan/pump. && 1st System Fan Speed Control (SYS_FAN1 Connector) Allows you to determine whether to enable the fan speed control function and adjust the fan speed. Normal Allows the fan to run at different speeds according to the system temperature. You can adjust the fan speed with System Information Viewer based on your system requirements. (Default) Silent Allows the fan to run at slow speeds. Manual Allows you to control the fan speed in the curve graph. Full Speed Allows the fan to run at full speeds. && 2nd System Fan Speed Control (SYS_FAN2 Connector) Allows you to determine whether to enable the fan speed control function and adjust the fan speed. Normal Allows the fan to run at different speeds according to the system temperature. You can adjust the fan speed with System Information Viewer based on your system requirements. (Default) Silent Allows the fan to run at slow speeds. Manual Allows you to control the fan speed in the curve graph. Full Speed Allows the fan to run at full speeds. && 3rd System Fan/Pump Speed Control (SYS_FAN3_PUMP Connector) Allows you to determine whether to enable the fan/pump speed control function and adjust the fan/pump speed. Normal Allows the fan/pump to run at different speeds according to the system temperature. You can adjust the fan/pump speed with System Information Viewer based on your system requirements. (Default) Silent Allows the fan/pump to run at slow speeds. Manual Allows you to control the fan speed in the curve graph. Full Speed Allows the fan/pump to run at full speeds. && 3rd System Fan/Pump Control Mode (SYS_FAN3_PUMP Connector) Auto Lets the BIOS automatically detect the type of fan/pump installed and sets the optimal control mode. Voltage Voltage mode is recommended for a 3-pin fan/pump. (Default) PWM PWM mode is recommended for a 4-pin fan/pump. BIOS Setup - 50 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

BIOS Setup
- 50 -
&
CPU OPT/Pump Fan Speed Control (CPU_OPT_PUMP Connector)
Allows you to determine whether to enable the fan/pump speed control function and adjust the fan/pump speed.
±
Normal
Allows the fan/pump to run at different speeds according to the CPU temperature. You
can adjust the fan/pump speed with System Information Viewer based on your system
requirements. (Default)
±
Silent
Allows the fan/pump to run at slow speeds.
±
Manual
Allows you to control the fan speed in the curve graph.
±
Full Speed
Allows the fan/pump to run at full speeds.
&
CPU OPT/Pump Fan Control Mode
±
Auto
Lets the BIOS automatically detect the type of fan/pump installed and sets the optimal
control mode.
±
Voltage
Voltage mode is recommended or a 3-pin fan/pump. (Default)
±
PWM
PWM mode is recommended or a 4-pin fan/pump.
&
1st System Fan Speed Control (SYS_FAN1 Connector)
Allows you to determine whether to enable the fan speed control function and adjust the fan speed.
±
Normal
Allows the fan to run at different speeds according to the system temperature. You
can adjust the fan speed with System Information Viewer based on your system
requirements. (Default)
±
Silent
Allows the fan to run at slow speeds.
±
Manual
Allows you to control the fan speed in the curve graph.
±
Full Speed
Allows the fan to run at full speeds.
&
2nd System Fan Speed Control (SYS_FAN2 Connector)
Allows you to determine whether to enable the fan speed control function and adjust the fan speed.
±
Normal
Allows the fan to run at different speeds according to the system temperature. You
can adjust the fan speed with System Information Viewer based on your system
requirements. (Default)
±
Silent
Allows the fan to run at slow speeds.
±
Manual
Allows you to control the fan speed in the curve graph.
±
Full Speed
Allows the fan to run at full speeds.
&
3rd System Fan/Pump Speed Control (SYS_FAN3_PUMP Connector)
Allows you to determine whether to enable the fan/pump speed control function and adjust the fan/pump speed.
±
Normal
Allows the fan/pump to run at different speeds according to the system temperature.
You can adjust the fan/pump speed with System Information Viewer based on your
system requirements. (Default)
±
Silent
Allows the fan/pump to run at slow speeds.
±
Manual
Allows you to control the fan speed in the curve graph.
±
Full Speed
Allows the fan/pump to run at full speeds.
&
3rd System Fan/Pump Control Mode (SYS_FAN3_PUMP Connector)
±
Auto
Lets the BIOS automatically detect the type of fan/pump installed and sets the optimal
control mode.
±
Voltage
Voltage mode is recommended for a 3-pin fan/pump. (Default)
±
PWM
PWM mode is recommended for a 4-pin fan/pump.