Gigabyte H470M DS3H User Manual - Page 42

C-3. Configuring Legacy RAID ROM, C-2. UEFI RAID Configuration

Page 42 highlights

3. After completing, you'll be brought back to the Intel(R) Rapid Storage Technology screen. Under RAID Volumes you can see the new RAID volume. To see more detailed information, press on the volume to check for information on RAID level, stripe block size, array name, and array capacity, etc. C-2. UEFI RAID Configuration Steps: 1. In BIOS Setup, go to Boot and set CSM Support to Disabled. Save the changes and exit BIOS Setup. 2. After the system reboot, enter BIOS Setup again. Then enter the Settings\IO Ports\Intel(R) Rapid Storage Technology sub-menu. 3. On the Intel(R) Rapid Storage Technology menu, press on Create RAID Volume to enter the Create RAID Volume screen. Enter a volume name with 1~16 letters (letters cannot be special characters) under the Name item and press . Then, select a RAID level. RAID levels supported include RAID 0, RAID 1, RAID 10, and RAID 5 (the selections available depend on the number of the hard drives being installed). Next, use the down arrow key to move to Select Disks. 4. Under Select Disks item, select the hard drives to be included in the RAID array. Press the key on the hard drives to be selected (selected hard drives are marked with "X"). Then set the stripe block size. The stripe block size can be set from 4 KB to 128 KB. Once you have selected the stripe block size, set the volume capacity. 5. After setting the capacity, move to Create Volume and press to begin. 6. After completing, you'll be brought back to the Intel(R) Rapid Storage Technology screen. Under RAID Volumes you can see the new RAID volume. To see more detailed information, press on the volume to check for information on RAID level, stripe block size, array name, and array capacity, etc. C-3. Configuring Legacy RAID ROM You'll need a discrete graphics card to enter the legacy RAID ROM utility. Enter the Intel® legacy RAID BIOS setup utility to configure a RAID array. Skip this step and proceed with the installation of Windows operating system for a non-RAID configuration. Steps: 1. In BIOS Setup, go to BIOS and set CSM Support to Enabled and Storage Boot Option Control to Legacy. Next, go to Settings\IO Ports\SATA And RST Configuration and make sure Use RST Legacy OROM is set to Enabled. Save the changes and exit BIOS Setup. After the POST memory test begins and before the operating system boot begins, look for a message which says "Press to enter Configuration Utility". Press + to enter the RAID Configuration Utility. 2. After you press + , the MAIN MENU screen will appear. If you want to create a RAID array, select Create RAID Volume in MAIN MENU and press . 3. After entering the CREATE VOLUME MENU screen, enter a volume name with 1~16 letters (letters cannot be special characters) under the Name item and press . Then, select a RAID level. RAID levels supported include RAID 0, RAID 1, RAID 10, and RAID 5 (the selections available depend on the number of the hard drives being installed). Press to proceed. 4. Under Disks item, select the hard drives to be included in the RAID array. If only two hard drives are installed, they will be automatically assigned to the array. Set the stripe block size if necessary. The stripe block size can be set from 4 KB to 128 KB. Once you have selected the stripe block size, press . 5. Enter the array capacity and press . Finally press on the Create Volume item to begin creating the RAID array. When prompted to confirm whether to create this volume, press to confirm or to cancel. 6. When completed, you can see detailed information about the RAID array in the DISK/VOLUME INFORMATION section, including the RAID level, stripe block size, array name, and array capacity, etc. To exit the RAID BIOS utility, press or select 6. Exit in MAIN MENU. Please visit GIGABYTE's website for details on configuring a RAID array. - 42 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

C-3. Configuring Legacy RAID ROM
You'll need a discrete graphics card to enter the legacy RAID ROM utility. Enter the Intel
®
legacy RAID BIOS
setup utility to configure a RAID array. Skip this step and proceed with the installation of Windows operating
system for a non-RAID configuration.
Steps:
1. In BIOS Setup, go to
BIOS
and set
CSM Support
to
Enabled
and
Storage Boot Option Control
to
Legacy
.
Next, go to
Settings\IO Ports\SATA And RST Configuration
and make sure
Use RST Legacy OROM
is
set to
Enabled
. Save the changes and exit BIOS Setup. After the POST memory test begins and before the
operating system boot begins, look for a message which says "Press <Ctrl-I> to enter Configuration Utility".
Press <Ctrl> + <I> to enter the RAID Configuration Utility.
2. After you press <Ctrl> + <I>, the
MAIN MENU
screen will appear. If you want to create a RAID array, select
Create RAID Volume
in MAIN MENU and press <Enter>.
3. After entering the
CREATE VOLUME MENU
screen, enter a volume name with 1~16 letters (letters cannot
be special characters) under the
Name
item and press <Enter>. Then, select a RAID level. RAID levels
supported include RAID 0, RAID 1, RAID 10, and RAID 5 (the selections available depend on the number of
the hard drives being installed). Press <Enter> to proceed.
4. Under
Disks
item, select the hard drives to be included in the RAID array. If only two hard drives are installed,
they will be automatically assigned to the array. Set the stripe block size if necessary. The stripe block size
can be set from 4 KB to 128 KB. Once you have selected the stripe block size, press <Enter>.
5. Enter the array capacity and press <Enter>. Finally press <Enter> on the
Create Volume
item to begin
creating the RAID array. When prompted to confirm whether to create this volume, press <Y> to confirm or
<N> to cancel.
6. When completed, you can see detailed information about the RAID array in the
DISK/VOLUME INFORMATION
section, including the RAID level, stripe block size, array name, and array capacity, etc. To exit the RAID
BIOS utility, press <Esc> or select
6. Exit
in
MAIN MENU
.
C-2. UEFI RAID Configuration
Steps:
1. In BIOS Setup, go to
Boot
and set
CSM Support
to
Disabled
. Save the changes and exit BIOS Setup.
2. After the system reboot, enter BIOS Setup again. Then enter the
Settings\IO Ports\Intel(R) Rapid Storage
Technology
sub-menu.
3. On the
Intel(R) Rapid Storage Technology
menu, press <Enter> on
Create RAID Volume
to enter the
Create
RAID Volume
screen. Enter a volume name with 1~16 letters (letters cannot be special characters) under the
Name
item and press <Enter>. Then, select a RAID level. RAID levels supported include RAID 0, RAID 1,
RAID 10, and RAID 5 (the selections available depend on the number of the hard drives being installed).
Next, use the down arrow key to move to
Select Disks
.
4. Under
Select Disks
item, select the hard drives to be included in the RAID array. Press the <Space> key
on the hard drives to be selected (selected hard drives are marked with "X"). Then set the stripe block size.
The stripe block size can be set from 4 KB to 128 KB. Once you have selected the stripe block size, set the
volume capacity.
5. After setting the capacity, move to
Create Volume
and press <Enter> to begin.
6. After completing, you'll be brought back to the
Intel(R) Rapid Storage Technology
screen. Under
RAID
Volumes
you can see the new RAID volume. To see more detailed information, press <Enter> on the volume
to check for information on RAID level, stripe block size, array name, and array capacity, etc.
Please visit GIGABYTE's website for details on configuring a RAID array.
3. After completing, you'll be brought back to the
Intel(R) Rapid Storage Technology
screen. Under
RAID
Volumes
you can see the new RAID volume. To see more detailed information, press <Enter> on the volume
to check for information on RAID level, stripe block size, array name, and array capacity, etc.
- 42 -