MP30-AR1 Quick Reference Guide 12 3 4 5 67 30 29 31 33 28 32 27 35 26 36 8 9 10 25 24 37 34 38 11 13 12 23 22 21 14 No. Code Description 1 LED_STA System status LED 2 USB2_MLAN KVM Server Management 10/100/1000 LAN port (top)/USB 2.0 ports (bottom) 3 VGA1_COM1 Serial port (top)/VGA port (bottom) 4 SFP+_1_2 SFP+ LAN port #1/#2 5 LAN1_2 GbE LAN port #1/#2 6 SW_PWR Power button with LED 7 SW_ID ID switch button with LED 8 CPU_FAN CPU fan connector 9 DIMM_P0_A0 Channel 1 slot 0 10 DIMM_P0_A1 Channel 1 slot 1 11 DIMM_P0_B0 Channel 2 slot 0 12 DIMM_P0_B1 Channel 2 slot 1 13 CPU0 AppliedMicro® X-Gene 1 processor 14 P12V_AUX 14 pin power connector 15 ATX1 24 pin main power connector 16 SYS_FAN1 System fan connector#1 17 FP_1 Front panel header (for Server system) 18 SYS_FAN2 System fan connector#2 19 PMBUS PMBus header 20 CLR_CMOS Clear CMOS jumper No. Code 21 SYS_FAN3 22 BP_1 23 CASE_OPEN 24 IPMB 25 SYS_FAN4 26 SATA_DOM0 27 SATA0 28 SATA1 29 SATA2 30 SATA3 31 PCIE_2 32 BAT 33 PCIE_1 34 LED_BMC 35 DIMM_P0_C0 36 DIMM_P0_C1 37 DIMM_P0_D0 38 DIMM_P0_D1 Description System fan connector#3 HDD back plane board header Case open intrusion alert header IPMB connector System fan connector#4 SATA port 3 DOM support jumper SATA 3 6Gb/s connector SATA 3 6Gb/s connector SATA 3 6Gb/s connector SATA 3 6Gb/s connector PCI Express x16 slot Battery socket PCI Express x16 slot BMC firmwar readiness LED Channel 3 slot 0 Channel 3 slot 1 Channel 4 slot 0 Channel 4 slot 1 Rear I/O Connector 1 3 5 No. Desription 1 GbE LAN ports 2 SFP+ LAN ports 2 2 3 7 4 5 Serial port VGA port KVM Server Management 10/100/1000 LAN port (Dedicated LAN port) 6 USB 2.0 ports 7 System Status LED 1 4 6 20 19 18 17 16 15 Speed LED Link/Activity LED ATX Power/ 䕚๕ IPMB SATA Connector/SATA 接口 24 13 12 1 No. Pin Define No. Pin Define 1 3.3V 13 3.3V 2 3.3V 14 -12V 3 GND 15 GND 4 +5V 16 PS_ON 5 GND 17 GND 6 +5V 18 GND 7 GND 19 GND 8 Power Good 20 -5V 9 5VSB 21 +5V 10 +12V 22 +5V 11 +12V 23 +5V 12 3.3V 24 GND 3 4 No. 1 2 1 2 Pin Define No. GND 3 GND 4 Pin Define +12V +12V No. Pin Define 1 31 Clock 2 GND 3 Data CPU/System FAN/ 䔎ࣂ 4 1 No. 1 1 2 3 4 4 Pin Define GND +12V Sense Speed Control 7 No. 1 2 3 4 1 Pin DefineNo. GND 5 TXP 6 TXN 7 GND Pin Define RXN RXP GND BMC Firmware Readiness LED BMC Firmware Readiness LED (LED_BMC): State Description On BMC firmware is initial Blink BMC firmware is ready Off AC loss Speed LED Link/Activity LED Speed LED Link/Activity LED Chassis Intrusion Alert Header Open: Normal operation. Closed: Active chassis intrustion alert. 1 No 1 2 3 5 PMBUS Pin Define No SMB CLK 4 SMB DATA 5 SMB ALERT Pin Define GND 3.3V SENSE Front Panel Header HDD Back Plane Board Header 2 2 24 No. Pin Define No. Pin Define 1 23 12 1 BP_SGP_CLK 2 No Connect 3 BP_SGP_LD 4 FAN_Gate No. Pin Define No. Pin Define 1 Power LED+ 2 5V Standby 3 No Pin 4 ID LED+ 5 Power LED- 6 ID LED- 7 HDD LED+ 8 System Status LED+ 9 HDD LED- 10 System Status LED- 11 Power Button 12 LAN1 Active LED+ 13 GND 14 LAN1 Link LED- 15 Reset Button+ 16 SMBus Data 17 GND 18 SMBus Clock 19 ID Switch+ 20 Case Open 5 7 9 11 13 15 17 25 26 19 21 23 25 BP_SGP_DOUT 6 Key Pin 8 GND 10 BP_LED_G_N 12 BP_SGP_DIN 14 GND 16 GND 18 P_3V3_AUX 20 P_3V3_AUX 22 GND 24 BP_PRESENSE 26 GND Reset BP_LED_A_N GND No Connect SMB_BP_DATA SMB_BP_CLK BMC_ACK BMC_REQ Key Pin GND 1 21 ID Switch- 22 LAN2 Active LED 23 NMI Switch- 24 LAN2 Link LED- 10/100/1000 LAN LED: State Yellow On Description 1Gbps data arte Green On 100Mbps data arte Off 10Mbps data arte SFP+ LAN LED: State Green On Description 10 Gbps data rate Green Blink Identify 10 Gbps data rate Yellow On 1 Gbps data rate Yellow Blink Identify 1 Gbps data rate Off 100 Mbps data rate System Status LED: State Description Green On Green Blink System is operating normally. Degrade condition, may indicates the following:  CPU failure  DIMM killed Amber On Critical condition, may indicates the following:  Power module failure  System fan failure  Power supply voltage issue  System temperature/voltage issue Amber Blink Non-critical condition, may indicates the following:  Redundant power module failure  Temperature and voltage issue  Chassis intrusion System is not ready. May indicate the following: POST error N/A NMI error Processor or terminator missing 系统状态LED: 说明 无亮灯 POST错误 NMI Jumper Settings Memory Population Configuration No. Desription 1 Clear CMOS Jumper 1-2 Close: Normal operation (Default setting) 2-3 Close: Clear CMOS data. 2 SATA Port 3 DOM Support Jumper Jumper 1-2 Close: Enable SATA port DOM support funtion. 2-3 Close: Normal Operation. (Default setting) If a SATA type hard drive is connected to the motherboard, please ensure the jumper is closed and set to 2-3 pins (Default setting), in order to reduce any risk of hard disk damage. Pin No. Definition 1 P5V 2 SATA3 Pin7 3 GND Slot Per Channel (SPC) and DIMM Per Channel (DPC) 1 Slot 2 Slot 4 Slot 8 Slot 1DPC 1DPC 2DPC A0+B0 A0+A1 A0 or C0 or or A0+C0 C0+C1 1DPC 2DPC 2DPC A0+B0 A0+A1+B0+B1 and or Inser Full C0+D0 A0+A1+C0+D0 PN

  • 1

MP30-AR1 Quick Reference Guide/
快速测试参考指南
No.
Code
Descrip°on
1
LED_STA
System status LED
2
USB2_MLAN
KVM Server Management 10/100/1000 LAN port (top)/USB 2.0 ports (bo±om)
3
VGA1_COM1
Serial port (top)/VGA port (bo±om)
4
SFP+_1_2
SFP+ LAN port #1/#2
5
LAN1_2
GbE LAN port #1/#2
6
SW_PWR
Power bu±on with LED
7
SW_ID
ID switch bu±on with LED
8
CPU_FAN
CPU fan connector
9
DIMM_P0_A0
Channel 1 slot 0
10
DIMM_P0_A1
Channel 1 slot 1
11
DIMM_P0_B0
Channel 2 slot 0
12
DIMM_P0_B1
Channel 2 slot 1
13
CPU0
AppliedMicro® X-Gene 1 processor
14
P12V_AUX
14 pin power connector
15
ATX1
24 pin main power connector
16
SYS_FAN1
System fan connector#1
17
FP_1
Front panel header (for Server system)
18
SYS_FAN2
System fan connector#2
19
PMBUS
PMBus header
20
CLR_CMOS
Clear CMOS jumper
No.
Code
Descrip°on
21
SYS_FAN3
System fan connector#3
22
BP_1
HDD back plane board header
23
CASE_OPEN
Case open intrusion alert header
24
IPMB
IPMB connector
25
SYS_FAN4
System fan connector#4
26
SATA_DOM0
SATA port 3 DOM support jumper
27
SATA0
SATA 3 6Gb/s connector
28
SATA1
SATA 3 6Gb/s connector
29
SATA2
SATA 3 6Gb/s connector
30
SATA3
SATA 3 6Gb/s connector
31
PCIE_2
PCI Express x16 slot
32
BAT
Ba±ery socket
33
PCIE_1
PCI Express x16 slot
34
LED_BMC
BMC firmwar readiness LED
35
DIMM_P0_C0
Channel 3 slot 0
36
DIMM_P0_C1
Channel 3 slot 1
37
DIMM_P0_D0
Channel 4 slot 0
38
DIMM_P0_D1
Channel 4 slot 1
1
2
3
4
5
6
7
8
9
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
28
29
30
27
31
32
33
34
35
36
37
38
11
10
2
1
Front Panel Header/
前面板
HDD Back Plane Board Header/
硬盤背板排針
1
24
23
2
No.
Pin Define
1
Power LED+
3
No Pin
5
Power LED-
7
HDD LED+
9
HDD LED-
11
Power Bu±on
13
GND
15
Reset Bu±on+
17
GND
19
ID Switch+
21
ID Switch-
23
NMI Switch-
No.
Pin Define
2
5V Standby
4
ID LED+
6
ID LED-
8
System Status LED+
10
System Status LED-
12
LAN1 Ac°ve LED+
14
LAN1 Link LED-
16
SMBus Data
18
SMBus Clock
20
Case Open
22
LAN2 Ac°ve LED
24
LAN2 Link LED-
12
25 26
No.
Pin Define
1
BP_SGP_CLK
3
BP_SGP_LD
5
BP_SGP_DOUT
7
Key Pin
9
GND
11
BP_LED_G_N
13
BP_SGP_DIN
15
GND
17
GND
19
P_3V3_AUX
21
P_3V3_AUX
23
GND
25
BP_PRESENSE
No.
Pin Define
2
No Connect
4
FAN_Gate
6
GND
8
Reset
10
BP_LED_A_N
12
GND
14
No Connect
16
SMB_BP_DATA
18
SMB_BP_CLK
20
BMC_ACK
22
BMC_REQ
24
Key Pin
26
GND
ATX Power/
电源
No.
Pin Define
1
3.3V
2
3.3V
3
GND
4
+5V
5
GND
6
+5V
7
GND
8
Power Good
9
5VSB
10
+12V
11
+12V
12
3.3V
No.
Pin Define
1
GND
2
GND
No.
Pin Define
13
3.3V
14
-12V
15
GND
16
PS_ON
17
GND
18
GND
19
GND
20
-5V
21
+5V
22
+5V
23
+5V
24
GND
2
1
4
3
No.
Pin Define
3
+12V
4
+12V
1
13
12
24
1
5
No
Pin Define
1
SMB CLK
2
SMB DATA
3
SMB ALERT
PMBUS
No
Pin Define
4
GND
5
3.3V SENSE
Memory Popula°on Configura°on/
安装内存
1 Slot
1DPC
1DPC
2DPC
A0 or C0
8 Slot
2DPC
Inser Full
A0+B0
or
A0+C0
1DPC
A0+B0
and
C0+D0
2DPC
A0+A1+B0+B1
or
A0+A1+C0+D0
A0+A1
or
C0+C1
2 Slot
4 Slot
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
Rear I/O Connector
/
后面板接口
Off
State
Description
Yellow On
1Gbps data arte
Green On
100Mbps data arte
10Mbps data arte
10/100/1000 LAN LED:
State
Description
Green On
Green Blink
Yellow On
Yellow Blink
Off
10 Gbps data rate
Identify 10 Gbps data rate
1 Gbps data rate
Identify 1 Gbps data rate
100 Mbps data rate
SFP+ LAN LED:
State
Description
Green On
System is operating normally.
Green Blink
Degrade condition, may indicates the following:
CPU failure
DIMM killed
Amber On
Critical condition, may indicates the following:
Power module failure
System fan failure
Power supply voltage issue
System temperature/voltage issue
Amber Blink
Non-critical condition, may indicates the following:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
N/A
System is not ready. May indicate the following:
POST error
NMI error
Processor or terminator missing
System Status LED:
Speed LED
Link/Ac°vity
LED
Speed LED
Link/Ac°vity
LED
Speed LED
Link/Ac°vity
LED
No.
Desrip°on
1
GbE LAN ports
2
SFP+ LAN ports
3
Serial port
4
VGA port
5
KVM Server Management 10/100/1000 LAN port (Dedicated LAN port)
6
USB 2.0 ports
7
System Status LED
系统状态LED:
绿色恒亮
绿色闪烁
橙色恒亮
橙色闪烁
颜色/状态
说明
系统正常运行
无亮灯
效能降低情形,可能为下列状况:
处理器问题
内存问题
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
SATA Connector/SATA
接口
No.
Pin Define
1
GND
2
TXP
3
TXN
4
GND
7
1
No.
Pin Define
5
RXN
6
RXP
7
GND
BMC Firmware Readiness LED
State
Descrip°on
On
BMC firmware is ini°al
Blink
BMC
firmware is ready
Off
AC loss
BMC Firmware Readiness LED (LED_BMC):
CPU/System FAN/
风扇
1
4
4
1
No.
Pin Define
1
GND
2
+12V
3
Sense
4
Speed Control
IPMB
No.
Pin Define
1
Clock
2
GND
3
Data
3
1
Jumper Se±ngs/
跳线设置
No.
Desrip°on
1
Clear CMOS Jumper
1-2 Close: Normal opera°on (Default se²ng)
2-3 Close: Clear CMOS data.
2
SATA Port 3 DOM Support Jumper Jumper
1-2 Close: Enable SATA port DOM support fun°on.
2-3 Close: Normal Opera°on. (Default se²ng)
If a SATA type hard drive is connected to the
motherboard, please ensure the jumper is
closed and set to 2-3 pins (Default se²ng),
in order to reduce any risk of hard disk
damage.
1
2
Definition
P5V
SATA3 Pin7
3
GND
Pin No.
Open: Normal opera°on.
Closed: Ac°ve chassis intrus°on alert.
Chassis Intrusion Alert Header
1
1
2
2
3
4
7
6
5
PN