>_]]VbTZR\ _^UZdZ_^Vb Item Model AD18LS1ERA Function cooling heating Capacity kW 5.0(1.8--6.0) 5.5(2.0--6.2) Sensible heat ratio 0.73 / Dehumidifying capacity 10‐³×m³/h 2.1 Power Supply 1PH,220-230V 50-60HZ Type × Number CENTRIFUGALX2 Fan Speed(H-M-L) r/min Fan motor output pow kW 730±30/540±30/400±30 0.05 Air-flow(H-M-L) m³/h 850/780/600 Static pressure Pa 25 Indoor unit Type / Diameter mm inner grooved pipe/φ7 Heat exchanger Total Area m² 0.34 Temp. scope ℃ 2-7 Dimension External (L×W×H)mm×mm×mm Package (L×W×H)mm×mm×mm 1090*500*220 1174*549*294 Drainage pipe (material , I.D./O.D.) mm 20/24 Control type (Remote / Wired) wired,YR-E14 Noise level ---sound presure (H-M-L) dB(A) 41/35/32 Noise level ---sound power (H-M-L) dB(A) 52/46/43 Weight (Net / Shipping) kg / kg 23/26.5 Refrigerant Type R410A PIPING Pipe Liquid Gas mm mm φ6.35 φ12.7 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃ DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -17-