>_]]VbTZR\ _^UZdZ_^Vb Item Function Model AD18LS1ERA cooling heating Capacity kW 5.0(1.8---6.0) 5.5(2.0---6.2) Sensible heat ratio 0.73 / Dehumidifying capacity Power Supply 10‐³×m³/h 2.1 1PH,220-230V 50-60HZ Type × Number centrifugal fan X 2 Fan Speed(H-M-L) Fan motor output power r/min kW 700±30 / 540±30 / 400±30 50 Air-flow(H-M-L) m³/h 850/780/600 Static pressure Pa 25 Indoor unit Type / Diameter mm inner grooved pipe/φ7 Heat exchanger Total Area m² 0.34 Temp. scope ℃ 2-7 Dimension External (L×W×H) Package (L×W×H) Drainage pipe (material , I.D./O.D.) Control type (Remote /wired) mm×mm×mm mm×mm×mm mm 1090×500×220 1174×549×294 20/24 wired, YR-E14 Noise level (H-M-L) dB(A) 41/35/32 Weight (Net / Shipping) kg / kg 23/26.5 Refrigerant Type R410A PIPING Pipe Liquid Gas mm mm Φ6.35 Φ12.7 Connecting Method FLARED Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -17-