>_]]VbTZR\ _^UZdZ_^Vb Item Model AC24CS1ERA Function cooling heating Capacity kW 6.3(2.0-7.3) 7.1(2.5-8.0) Sensible heat ratio 0.72 / Dehumidifying capacity 10‐³×m³/h 2.0 Power Supply 1PH,220-230VAC,50HZ Type × Number centrifugal*2 Fan Speed(H-M-L) Fan motor output power r/min kW 1220±40/1190±50/1050±50/980±50 0.10 Air-flow(H-M-L) m³/h 800/720/650 Indoor unit Type / Diameter mm inner grooved pipe/φ7 Heat exchanger Total Area m² 0.49 Temp. scope ℃ 2-7 Dimension External (L×W×H) mm×mm×mm Package (L×W×H) mm×mm×mm 990*665*199 1150*750*300 Drainage pipe (material , I.D./O.D.) mm PVC 18/20 Control type (Remote /wired) remote, YR-HD Noise level (H-M-L) dB(A) 48/46/44 Weight (Net / Shipping) kg / kg 28.3/34.3 Refrigerant Type R410A PIPING Pipe Liquid Gas mm mm 9.52 15.88 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -19-