Haier AC282AFEAA User Manual - Page 16

Connection Pipe Requirement

Page 16 highlights

Installation of Indoor Unit CONNECTION PIPE REQUIREMENT Table 1 Model Diameter Liquid side Gas side Maximum length For series 362*EAA),422,482, 522, 602 For series 282, 362(ERA) 9.52 mm 9.52 mm 19.05mm 15.88mm 50 m 30 m Maximum height (between indoor and outdoor) 30 m 20 m INSTALLATION PROCEDURE Install the room air conditioner as follows: 1. REMOVE THE INTAKE GRILL AND SIDE COVER Air filter (1) Remove the Air filters (2) Remove the intake grilles (3) Remove the Side cover A (Right and left side) Intake grille (4) This air conditioner can be set up to intake fresh air . For information about how to install for Side cover A (Right side) Side cover A (Left side) fresh-air intake, refer to page 22 "FRESH-AIR INTAKE". 2. LOCATION OF CEILING SUSPENSION BOLTS Fig. 3 30mm Suspension bolt pitch 1530mm 30mm Dimensions (Space Required for installation) 10mm 155mm INDOOR UNIT (TOP VIEW) 300mm Suspension bolt should extend outward 30 to 50mm. For half-concealed installation Supension-bolt pitch should be as shown in Fig.4. Fig. 4 40mm Ceiling Opening:1530mm 40mm Ceiling panel Ceiling Opening:640mm 15mm Ceiling panel Suspension bolt should extend outward 30 to 50mm. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

INSTALLATION PROCEDURE
Install the room air conditioner as follows:
CONNECTION PIPE REQUIREMENT
Table 1
Model
Diameter
Liquid side
Gas side
Maximum
length
Maximum height
(between indoor
and outdoor)
9.52 mm
19.05mm
50 m
30 m
14
Installation of Indoor Unit
1. REMOVE THE INTAKE GRILL AND SIDE COVER
(1) Remove the Air filters
2. LOCATION OF CEILING SUSPENSION BOLTS
For half-concealed installation
Supension-bolt pitch should be as shown in Fig.4.
Ceiling Opening:1530mm
40mm
40mm
Ceiling panel
Suspension bolt should
extend outward 30 to 50mm.
Ceiling Opening:640mm
Ceiling panel
15mm
(2) Remove the intake grilles
(3) Remove the Side cover A (Right and left side)
(4) This air conditioner can be set up to intake
fresh air . For information about how to install for
fresh-air intake, refer to page 22 "FRESH-AIR INTAKE".
Suspension bolt should
extend outward 30 to 50mm.
Suspension bolt pitch 1530mm
30mm
30mm
INDOOR UNIT (TOP VIEW)
Dimensions
(Space
Required for
installation)
10mm
155mm
300mm
Fig. 3
Fig. 4
Side cover A (Right side)
Side cover A (Left side)
Intake grille
Air filter
9.52 mm
15.88mm
30 m
20 m
For series 362
*EAA),
422,
482
,
522, 602
For series 282, 362(ERA)