Haier ES10V-M1 User Manual - Page 4

Haier ES10V-M1 Manual

Page 4 highlights

Parameters Dimensions Parameters ES10V-M1 ES15V-M1 ES25V-M1 Rated voltage V Rated frequency Hz Rated pressure MPa Power W Net weight Kg Rated temperature ℃ Volume L Dimension mm Waterproof grade / Mixing factor / Tap water pressure / Average temperature of hot water outlet ℃ Re-heating time (temperature rise 50℃) S Diameter of power wire m m2 Outlet rate of hot water % 24h fixed COP / 230 50 0.80 2000 8 75 10 See to Figure 1 IPX4 230 50 0.80 2000 10 75 15 See to Figure 1 IPX4 230 50 0.80 2000 14 75 25 See to Figure 1 IPX4 No less than 0.05MPa No less than 0.05MPa Nolessthan0.05MPa 3×1 . 5 3×1 . 5 3×1 . 5 Remarks: The permitted error or limit of net weight above is ±10%. Dimensions (Figure 1) Front view a Side view Cutaway vie w Rear vie w C G F D d c E e b B A Model a b c d e ES10V-M1 298 287 501 152 100 ES15V-M1 318 300 623 152 100 ES25V-M1 378 374 616 152 100 A Hot water outlet B Cold water inlet C Tank D Heating element F Thermometer tube G Wall-mounting bracket Remarks: The permitted error or limit of the above parameters is ±10%. E Anode rod 2 Usage Cleaning and maintenance Usage After installation, as the tank is empty in the first usage, be sure to open the tap water inlet valve and mixing valve. When the tank is filled with water, and the shower nozzle or other water outlet keeps the water output, please close the mixing valve, check if ther水e 。 is water leakage at each joint and plug the power. Turn the knob as per the needed water temperature. The mark of the knob increases from water inlet temperature to 75℃æthe heating temperature steplessly. The heating indicator will light on under heating mode. Generally, the knob should be set to the highest scale. The water heater can regulate the temperature automatically. The power will be switched off automatically when the set temperature is reached, and will be switched on automatically when the temperature drops to a certain level. As it continues heating, you can use hot water as well. When the tap water inlet pressure arrives at or exceeds 0.80MPa, the drain hose of safety valve will discharge a large amount of water. It is due to extra high water pressure. Please contact the local after service agent for disposal. In long-term out-of-use or maintenance of the heater, you can close the city water pipe valve and set the mixing valve to the highest water temperature rate after opening the safety valve handle. Move up the safety valve handle to drain the tank. To avoid injury, before the next use, it is suggested to first open hot water valve before switching on the water heater, exhaust gas possibly retained in the pipeline. In this case, no smoke or fire is permitted near the open valve. Carefully check and confirm all parts are in good condition. Cleaning and maintenance Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little mild detergent. Do not use gasoline or other solvents. Finally dry with a dry cloth. Keep water heater dry. To ensure high working efficiency, heating elements and tank liner of water heater shall be cleaned once every three years. Take care not to damage the protection layer on heating elements and tank liner surface. According to the local water quality, magnesium rod shall be periodically replaced. If maintenance is needed, please contact a local service station. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6