Haier ESA406P -manual - Page 8
Location Requirements - room air conditioners
View all Haier ESA406P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
ENGLISH LOCATION REQUIREMENTS IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. THE LOCATION SHOULD PROVIDE: • A grounded electrical outlet within 6 ft. (183 cm) of where the power supply cord exits the air conditioner, for models: ESA405P, ESA406P, ESA406N, ESA408N • A grounded electrical outlet within 4 ft. (122 cm) of where the power supply cord exits the air conditioner, for models: ESA410N, ESA412N NOTE: Do not use an extension cord, plug adapter, surge protector or multi-outlet adapter. • Free movement of air in the room to be cooled. • A large enough window opening for the air conditioner. (See Fig.2) • The air conditioner must not be installed in a through-the-wall sleeve or in a wall. It can only be installed in a double-hung window. NOTE: The outside cabinet louvers and air discharge must not be obstructed by bushes, trees, etc. Air must be able to pass freely through the cabinet louvers. (See Fig.1) Fig. 1 Fig. 2 CABINET LOUVERS WIDTH WWiInNdDowOWopeINniSnTgAmLLEeNLGaATsHTurIeOmNents: A. Width B. Height ESA405P 21-7/8" - 36" 13-3/8" ESA406P, ESA406N 24-1/2" - 36" 13-3/8" AIR DISCHARGE WIDTH B-HEIGHT A-WIDTH ESA408N / ESA410N ESA412N 25" - 36-21/32" 26-1/8" - 37-25/32" 14-9/16" 14-9/16" PAGE 6 INSTALLATION REQUIREMENTS