Haier HFU-12HA03 User Manual - Page 28
Purging Method, For R410A, Close
View all Haier HFU-12HA03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Installation Manual of Room Air Conditioner 3. Piping connection of the outdoor unit Connecting the connecting pipe and inlet and outlet liquid pipe according to the piping method Purging Method:(For R410A) Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (low) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump. Open the handle at low in gaugemanifold, operate vacuum pump. If the scale-moves of gause (low) reach vacuum condition in a moment, check again. Liquid Side 6.35mm(1/4") Gas Side 9.52mm(3/8") 12.7mm(1/2") 2-way valve 3-way valve Gaugemanifold(for R410A) Anti countercurrent joint Tube(for R410A) Vacuum pump(for R410A) Open Vacuumize for over 15min. And check the level gauge which should read -0.1 MPa (-76 cm Hg) at low pressure side. After the completion of vacuumizing, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump. Check the condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of . Close Open the valve rod for the 2-way valve to an angle of anticlockwise 90 degrees. After 6 seconds, close the 2-way valve and make the inspection of gas leakage. No gas leakage? In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps. 2-way valve 3-way valve Open 90o Service port 90ofor 6 sec. If it does not stop gas leakage, discharge whole refrigerants from the service port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder Detach the charge hose from the service port, open 2-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly. To prevent the gas leakage, turn the service port's cap, the valve rod's cap for 2-way valve and 3-way's a little more than the point where the torque increases suddenly. After attaching the each caps, check the gas leakage around the caps. 2-way valve 3-way valve Liquid Side 6.35mm(1/4") 2-way valve Gas Side 9.52mm(3/8") 12.7mm(1/2") 3-way valve 2-way valve 3-way valve HFU-09HA03/R2(DB) HFU-12HA03/R2(DB) HFU-18HA03/R2(DB) Service port cap Valve rod cap Valve rod cap CAUTION: 1.If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. 2.Please do not let other cooling medium, except specified one (R410A), or air enter into the cooling circulation system. Otherwise, there will be abnormal high pressure in the system to make it crack and lead to personal injuries. 27