Haier HGRP241AAWW User Manual - Page 14
For a Harper-Wyman
UPC - 688057370828
View all Haier HGRP241AAWW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
To Convert and/or Adjust 1. Convertible Pressure Regulator The inlet pressure of the gas supply shall be in accordance with the nominal inlet pressure of the regulator used on the range or 1/2 psig maximum. The range should be tested by pressurizing the regulator with an inlet pressure at least 1 inch water column above the manufacturer's specified manifold pressure shown on the serial plate. The range will be equipped with one of the two types of regulators shown. For a Harper-Wyman regulator, remove converter cap by inserting a coin into slot in top and twisting. Turn cap over and re-install. On the SCP regulator, unscrew the converter using a 5/8'' wrench. Turn the cap over and reinstall. On the Maxitrol regulator, unscrew the brass converter cap using a 7/8" wrench. Turn the selector pin over and re-install. Note: What you read on the converter cap or plunger is the type of gas for which the regulator is set. If yours reads NAT, the regulator is set for natural gas. If yours reads LP, the regulator is set for LP. 14