Haier HPRD12XH5 User Manual - Page 11

Control Panel

Page 11 highlights

English Control Panel Power Control The power control turns the unit on and off. Warning Light Do not operate the unit if this light is lit. Please call the service number and bring the unit into your nearest service center. Dehumidifier Mode • Air is dehumidified as it passes through the air conditioner, without being in full cooling mode. (Note: The warm air exhaust hose must vent inside the room, not outside as it does when cooling. If the unit is vented outside some cooling will occur.) Mode Control The mode control has 3 settings: • Cool • Dehumidifier • Heating (only HPRD12XH5)/Fan The settings are adjusted with Mode Control button. A green light will indicate which setting is currently being used. Cooling Mode • During the cooling mode the air is cooled and hot air is exhausted to the outside air through the exhaust tube. • Adjust fan speed and temperature to suit your desired comfort level. Heating Mode (Led in Red) (only HPRD12XH5) • In heating mode, the air flow is selectable. (Note: Heating is activated only when the ambient temperature is below 77˚ F.) Fan Mode (Led in Yellow) • Air is circulated throughout the room with no cooling. (Note: Unit does not need to be vented in Fan mode.) Fan Speed The Fan Speed Control has three settings: High, Medium or Low. In the Dehumidifier or Dry Mode, the fan will only operate at low speed. (10)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

English
(10)
Control Panel
Power Control
The power control turns the unit on and off.
Warning Light
Do not operate the unit if this light is lit. Please call
the service number and bring the unit into your
nearest service center.
Mode Control
The mode control has 3 settings:
• Cool
• Dehumidifier
• Heating
(only HPRD12XH5)
/Fan
The settings are adjusted with Mode Control button.
A green light will indicate which setting is currently
being used.
Cooling Mode
• During the cooling mode the air is cooled
and hot air is exhausted to the outside air
through the exhaust tube.
Adjust fan speed and temperature to suit
your desired comfort level.
Dehumidifier Mode
• Air is dehumidified as it passes through the
air conditioner, without being in full cooling
mode. (Note: The warm air exhaust hose
must vent inside the room, not outside as it
does when cooling. If the unit is vented
outside some cooling will occur.)
Heating Mode (Led in Red)
(only HPRD12XH5)
• In heating mode, the air flow is selectable.
(Note: Heating is activated only when the
ambient temperature is below 77˚ F.)
Fan Mode (Led in Yellow)
• Air is circulated throughout the room with no
cooling. (Note: Unit does not need to be
vented in Fan mode.)
Fan Speed
The Fan Speed Control has three settings: High,
Medium or Low. In the Dehumidifier or Dry Mode,