Operation
View all Haier HSM09HRAC03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Operation Base Operation Remote controller 1. Unit start Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT 3.Select temp.setting Press TEMP+ TEMP- button TEMP+ Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly TEMP- Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. Operation Mode AUTO Display Board Remote Controller Note Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. COOL DRY HEAT In DRY mode, when room temperature becomes lower than temp.setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting. FAN nothing In FAN operation mode , the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available. Emergency operation and test operation Emergency Operation: Pi Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes,cooling or fan or heat, according to the room. temperature. Room Operation Designated Timer temperature mode temperature mode Air flow ABOVE 23OC COOLING 26OC NO AUTOMATIC BELOW 23OC HEAT 23OC NO AUTOMATIC (Cooling only uint˅ Operation Designated Room temperature mode temperature BELOW 23OC FAN 26OC It is not possible to operate in dry mode. Timer mode NO Air flow AUTOMATIC Test operation: Test operation switch is the same as emergency switch. Use this switch in the test operation when the room temperature is below 16oC, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi". Pi Pi Air Flow Direction Adjustment 1.Status display of air flow Vertical flap Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 (Auto swing) 2.Left and right air flow adjustment(manual) Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig. Cautions: When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur. Note: When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. 3