Haier HSU-09HEA13-B User Manual - Page 4
Operation
View all Haier HSU-09HEA13-B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Operation HEALTH Operation (This function is unavailable on some models.) SWING CLOCK SLEEP HEALTH POWER/SOFT LOCK RESET The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. POWER/SOFT Operation (This function is unavailable on some models.) (1) POWER Operation When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically SWING CLOCK takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically SLEEP HEALTH POWER/SOFT takes medial speed of AUTO fan mode. LOCK RESET To cancel POWER operation Press POWER/SOFT button twice ,POWER/SOFT disappears. (2) SOFT Operation You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed SWING CLOCK automatically takes low speed of AUTO fan mode. SLEEP HEALTH POWER/SOFT LOCK RESET Healthy Negative ions TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically a following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. (1) TIMER ON MODE FAN SWING SET TIMER CLOCK MODE FAN SWING SET TIMER CLOCK (2) TIMER OFF MODE FAN SWING SET TIMER CLOCK MODE FAN SWING SET TIMER CLOCK MODE FAN SWING SET TIMER CLOCK (3) TIMER ON-OFF (This function is unavailable on some models.) MODE FAN SWING SET TIMER CLOCK MODE FAN SWING SET TIMER CLOCK MODE FAN SWING SET TIMER CLOCK MODE FAN SWING SET TIMER CLOCK To cancel TIMER mode Just press TIMER button several times untilTIMER mode disappears. 3 To cancel SOFT operation Press POWER/SOFT button again ,POWER/SOFT disappears. Emergency operation and test operation Emergency Operation: Pi Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes,cooling or fan or heat,according to the room temperature. Room Operation Designated Timer temperature mode temperature mode Air flow ABOVE 23OC COOLING 26OC NO AUTOMATIC BELOW 23OC HEAT 23OC NO AUTOMATIC (Cooling only uint) Room temperature Operation Designated mode temperature BELOW 23OC FAN 26OC It is not possible to operate in dry mode. Timer mode NO Air flow AUTOMATIC Test operation: Test operation switch is the same as emergency switch. Use this switch in the test operation when the room temperature is below 16oC, do not use it in the normal operation. Pi Pi Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice,release your finger from the switch: the cooling operation starts with the air flow speed "Hi". After 30 minutes, test operation ends automatically(Only for 22K,24K unit).