Haier HSU-09LEA03-N User Manual - Page 3
Indoor unit
View all Haier HSU-09LEA03-N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 12 34 Indoor unit HSU-09LEA13-W HSU-09LEA13-F HSU-09CRA03-T HSU-09LEA03-N Outdoor unit HSU-05LEA03 HSU-07LEA03 HSU-09LEA03 HSU-09LEN03 HSU-12LEA13-W Indoor unit 2X0.75mm { power plug HSU-22LEA03 HSU-24LEA03 Outdoor unit Indoor unit LN 3X2.5mm Power cable: 3G2.5mm AMS18H03-N Outdoor unit HSU-18HEA13(T3) HSU-18HEA03(T3) 1(N) 2(L) Power cable: 3G1.0mm 2X0.75mm 3X1.0mm 1(N) 2(L) 3(C) 1 ) 2((N) 3(C) Indoor unit HSU-18LEA03 HSU-18LEA13-W HSU-22LEA13-W HSU-09LEA13-H HSU-12LEA13-H HSU-14LEA13-H HSU-18LEA13-H HSU-18LEA03-T HSU-12LEA13-F HSU-12LEA03 Outdoor unit HSU-09LEB13-H HSU-12LEB13-H HSU-14LEB13-H HSU-12LEA13-M HSU-18LEA13-M HSU-18LEA03(T3) HSU-18LEA13(T3) HSU-10LEA03-T HSU-13LEA03-T HSU-18LED03-T HSU-10LED03-T Indoor unit HSU-07HEA03 HSU-09HEA03 AMS12H03-N HSU-09HEC03 HSU-12HEC03 AMS09H03-N Outdoor unit Indoor unit Outdoor unit HSU-12HEB03 HSU-12HEA03/(DB) HSU-09HEA03/(DB) YKS-09HEA03 HSU-12HEA03/(BP) HSU-09HEA03/(BP) 6G0.75mm connecting wiring: -mod 09-12: 3G1.5mm +1X0.75mm Power cable: -mod 09-12: 3G1.0mm 12 3 4 5 Power cable: HSU-12LEN03 HSU-18LEN03 connecting wiring: HSU-13LED03-T HSU-18LED03-T1 -mod 05-13: 3G1.0mm -mod 18: 3G2.0mm Indoor unit 3G2.5mm HSU-22HEA03 HSU-24HEA03 AMS22H03-N YKS-22HEA03 N L Outdoor unit POWER Power cable: -mod 12: 3G1.0mm -mod 18: 3G2.5mm HSU-22LEA13-W : 3G2.0mm -mod 22 24: 4G0.75mm 2X0.75mm 3G2.5mm 1(L) 2(N) 3 4 Power cable: -mod 05-13: 3G1.0mm -mod 18: 3G1.5mm -mod 22 24 :3G2.5mm 3X1.0mm Power cable: Indoor unit 3G2.5mm Outdoor unit HSU-18HEA03 YKS-12HEA03 HSU-12HEA03 YKS-18HEA03 Indoor unit HSU-12CRA03-T HSU-18CRA03-T Outdoor unit PAS18L03-N(T3) 3