Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units The models adopt HFC free refrigerant R410A Accessory parts No. Accessory parts 1 Remote controller Number of articles 1 Optional parts for piping Mark Parts name A Non-adhesive tape 2 R-03 dry battery 2 B Adhesive tape C Saddle(L.S) with screws 3 1 D Connecting electric cable for indoor and outdoor Mounting plate E Drain hose 4 4X25 Screw Plastic cap 4 F Heating insulating material G Piping hole cover 5 Drain-elbow 1 6 1 Pipe supporting plate more than 10cm Arrangement of piping directions Rear left Left Rear right Right Below more than 10cm more than 5cm Attention must be paid to the rising up of drain hose A more than 10cm C more than 10cm D No.0010562727 more than 60cm The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. more than 15cm

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

No.001056
2727
Installation Manual of Room Air Conditioner
Drawing for the installation of indoor and outdoor units
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
The models adopt HFC free refrigerant R410A
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain-elbow
1
1
2
3
4
5
6
2
1
4
1
1
Number
of
articles
Accessory parts
Pipe supporting plate
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from
to
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to
the rising up of drain hose
more than 5cm
more than 10cm
more than 10cm
more than 10cm
more than 60cm
more than 15cm
more than 10cm
A
C
D
Screw
Plastic cap
4X25