Haier HSU-12HVA103 User Manual - Page 1
Haier HSU-12HVA103 Manual
View all Haier HSU-12HVA103 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units The models adopt HFC free refrigerant R410A Accessory parts No. Accessory parts 1 Remote controller Number of articles 1 2 R-03 dry battery 2 3 1 Optional parts for piping Mounting plate Mark Parts name 4 1 A Non-adhesive tape Drain hose B Adhesive tape 5 4X25 Screw Plastic cap 4 6 Drain-elbow 1 C Saddle(L.S) with screws D Connecting electric cable for indoor and outdoor E Drain hose F Heating insulating material 7 Cushion 4 G Piping hole cover more than 10cm Arrangement of piping directions Rear left Left Rear right Right Below more than 5cm G Attention must be paid to the rising up of drain hose A more than 10cm F more than 10cm C more than 10cm No.0010 D E more than 60cm more than 15cm The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m.