Haier HSU-18HEK03 User Manual - Page 1

Haier HSU-18HEK03 Manual

Page 1 highlights

Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units Accessory parts No. Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for indoor and outdoor 4 1 E Drain hose Drain hose F Heating insulating material 5 4X50 Steel nail, cement 6 G Piping hole cover 6 4X25 Screw Plastic cap 4 7 Drain-elbow 1 8 Cover 1 9 Cushion 4 10 1 Pipe supporting plate 11 Connecting cable 1 Arrangement of piping directions Rear left Left Rear right Right Below more than 10cm more than 10cm Note:Cooling only units don't have Drain-elbow more than 5cm Attention must be paid to the rising up of drain hose A more than 10cm C more than 10cm D E No.0010518787 more than 60cm more than 15cm The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m.

  • 1
  • 2
  • 3
  • 4

Installation Manual of Room Air Conditioner
No.0010518787
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from
to
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to
the rising up of drain hose
m
c
5
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
A
C
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Steel nail, cement
Screw
Plastic cap
Drain-elbow
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
10
2
1
1
6
4
1
1
4
1
Number
of
articles
Accessory parts
4X50
4X25
Pipe supporting plate
11
Connecting cable
1
m
c
0
1
n
a
h
t
e
r
o
m
m
c
0
6
n
a
h
t
e
r
o
m
m
c
5
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
D
E
Note:Cooling only units don't have Drain-elbow
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation