Haier HSU-18LEA03 User Manual - Page 15

Emergency operation and test operation

Page 15 highlights

Operation Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the " Pi "sound is heard once, which means the start of this operation. Pi In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature: Room Designated temperature temperature Above 23oC 26oC Below 23oC 23oC Timer mode No No Fan Operation speed mode AUTO COOL AUTO HEAT It is impossible to change the settings of temp.and fan speed,It is also not possible to operate in timer or dry mode. If an air conditioner is a model for both cooling and heating. Cooling when the room temperature at the start of operation is above 23oC. Heating when the room temperature at the start of operation is below 23oC Test operation: Test operation switch is the same as emergency switch. Pi Pi Use this switch in the test operation when the room temperature is below 16oC, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi". Removal of the restriction of emergency or test operation: Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Emergency Operation:
Pi Pi
Emergency operation and test operation
Operation
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed, the " Pi "sound is
heard once, which means the start of this operation.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
operation starts with the air flow speed "Hi".
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling
Removal of the restriction of emergency or test operation:
Pi
When the remote controller is manipulated, it gets the system back to the
normal operation mode.
Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.
In this operation, the system automatically selects the operation
modes, cooling or heating, according to the room temperature:
It is impossible to change the settings of temp.and fan
speed,It is also not possible to operate in timer or dry mode.
Test operation switch is the same as emergency switch.
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 23
o
C
Below 23
o
C
23
o
C
26
o
C
No
AUTO
AUTO
COOL
HEAT
Heating when the room temperature at the start of operation is below 23
o
C
If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23
o
C.
No
14