Connecting the indoor/outdoor Electric Cable - y2
View all Haier HSU-18LEK03-Y3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Power cable: Power cable: 3G1.0mm 1 / Power cable: 3G2.5mm -mod 09-12: 3G1.0mm 2 -mod 18: 3G1.5mm 2 1(L) 2 (N) & 4G0.75mm Indoor unit HSU-24LEK13 HSU-24LK2S3 HSU-24LEK03-Y2 L POWER N HSU-22LD11 HSU-22LB11 Outdoor unit / 1 Indoor unit HSU-108CH09 HSU-138CH09 Outdoor unit HSU-09LEK03(DB) HSU-12LEK03(DB) 3G1.0mm Indoor unit HSU-09CK2S3 HSU-09LEK13 HSU-12LEK13 HSU-07LEK03 HSU-09LB11T HSU-09LD11T HSU-05LEK03-Y Indoor unit HSU-12LD11T HSU-12LB11T HSU-12LD11 HSU-09LB11 Outdoor unit HSU-12LEK03-Y3 HSU-09LEK03-Y3 HSU-12LEK13-M SAS-09HEK3 SAS-12HEK3 SAS-18HEK3 HSU-09HH03 HSU-09LD11 HSU-12LEK03-Y2 HSU-09CK2W3 HSU-09LEK03-Y HSU-09CK6B3 HSU-09LEK03-Y2 HSU-09LEK03 HSU-12CK2W3 HSU-09LEK03-Y5 HSU-12LEK03 HSU-12CK6B3 HSU-12LEK03-Y5 HSU-12CK2S3 HSU-09LH03 HSU-07LEK03-Y HSU-12LB11 HSU-12LH03 HSU-12LEK03-Y HSU-18LB11T HSU-18LEK03-Y3 HSU-18LEK13 HSU-18LD11T HSU-18LEK03-Y2 HSU-18LK2S3 HSU-18LD11 HSU-18LEK03-Y HSU-18LK6B3 Indoor unit HSU-18LB11 HSU-18LEK03 HSU-18LK2W3 HSU-12LEK03-Y6 HSU-12HEK03 HSU-07HEK03 Outdoor unit HSU-09HEK03 HSU-09HEG03 HSU-18HEK03 HSU-12HEG03 HSU-12HH03 Power cable: 3G2.5mm 4G0.75mm HSU-18LH03 HSU-24LD11T HSU-24LEK03-Y3 HSU-18LEK03-Y5 HSU-18LEK03-Y6 Outdoor unit Power cable: 3G2.5mm 6G0.75mm Power cable: 3G2.5mm 4G0.75mm Power cable: 3G1.5mm 4G0.75mm 2 Indoor unit SAS-24HEK3 HSU-18HH03 HSU-18HEG03 t HSU-24HEK03 HSU-24HH03 Outdoor uni HSU-24HEG03 BR BL POWER SUPPLY Y/G /1 /1 Indoor unit HSU-24LEK03-Y5 HSU-24LH03 Outdoor unit BR BL POWER SUPPLY Y/G 3 Indoor unit { POWER HSU-18LEK03/(DB) Outdoor unit