Haier HSU-36LEA03 User Manual - Page 1
Haier HSU-36LEA03 Manual
View all Haier HSU-36LEA03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units more than 5cm Accessory parts No. Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for indoor and outdoor 4 1 E Drain hose Drain hose F Heating insulating material 5 4X50 Steel nail, cement 6 G Piping hole cover more than 10cm 6 4X25 Screw Plastic cap 4 7 Cover 1 8 Cushion 4 9 Pipe supporting plate 1 10 Drain-elbow 1 Arrangement of piping directions Rear left Left Rear right Right Below more than 10cm more than 60cm Attention must be paid to the rising up of drain hose A more than 10cm C more than 10cm D E more than 15cm No.0010518785 The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m.