Installation Guide The installation of air conditioner(only for reference) 1. Cut a wall hole or a window hole (see Fig.1). A B HW-07)OO( HW-09XXX 350 530 AW09XXXXXX HW-10XXX HW-12)OO( 410 570 HW-18)OO( 438 670 2. Fix the iron support in a firm place with expansible screws. 3. Take the air conditioner and its attachments out from the packing carton. 4. Let the rear of the air conditioner raise slightly, the drain hole on the bottom can be seen. Clog it with a black rubber stopper attached to the air conditioner (see Fig.2). Iron support Thickness of the wall Fig.1 Condenser Fig.2 C. Rubber stopper / 5. Insert the drain connecting pipe (with a seal circle) attached to the air conditioner into the vertical drain hole on the bottom (see Fig. 3). (For heat pump; for cooling only type, connect drain hose as shown in Fig. 4) 6. The condensate needing to be led to the designated place, buy a soft plastic pipe with internal diameter of 16mm to connect the drain connecting pipe and tied it tightly. 7. All attachments being fixed, put the air conditioner on the iron support. If there is a drain hose, lead it to a required place (see Fig.5) not for HW-18xxx. . I III \ 0 Fig.3 Seal circle - Drain hose Drain connecting / pipe Fig.4 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Installation
Guide
The
installation
of
air
conditioner(only
for
reference)
1.
Cut
a
wall
hole
or
a
window
hole
(see
Fig.1).
A
B
HW-07)OO(
HW-09XXX
AW09XXXXXX
350
530
HW-10XXX
HW-12)OO(
410
570
HW-18)OO(
438
670
2.
Fix
the
iron
support
in
a
firm
place
with
Fig.1
expansible
screws.
Condenser
Iron
support
Thickness
of
the
wall
3.
Take
the
air
conditioner
and
its
attach-
ments
out
from
the
packing
carton.
4.
Let
the
rear
of
the
air
conditioner
raise
slightly,
the
drain
hole
on
the
bottom
can
be
seen.
Clog
it
with
a
black
rubber
stopper
attached
C.
Rubber
stopper
/
to the
air
conditioner
(see
Fig.2).
Fig.2
5.
Insert
the
drain
connecting
pipe
(with
a
seal
.
I
I
I
I
circle)
attached
to
the
air
conditioner
into
the
vertical
drain
hole
on
the
bottom
(see
Fig.
3).
(For
heat
pump;
for
cooling
\
0
only
type,
connect
drain
hose
as
shown
in
Fig.
4)
Fig.3
6.
The
condensate
needing
to
be
led
to
the
designated
place,
buy
a
soft
plastic
pipe
with
internal
diameter
of
16mm
to
connect
the
drain
connecting
pipe
and
tied
it
tightly.
Drain
connecting
7.
All
attachments
being
fixed,
put
the
air
Seal
circle
/
pipe
conditioner
on
the
iron
support.
If
there
Drain
hose
is
a
drain
hose,
lead
it
to
a
required
place
(see
Fig.5)
not
for
HW-18xxx.
Fig.4
11