Hamilton Beach 49960 Use and Care Manual - Page 10
Problem, Probable Cause/solution
View all Hamilton Beach 49960 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Troubleshooting (cont.) PROBLEM Coffee not dispensing. Failed foil seal. PROBABLE CAUSE/SOLUTION • Piercing needle is clogged with coffee grounds. Turn unit off; unplug. Allow unit to cool completely. To remove any built-up coffee grounds, insert end of bent paper clip into eye and up into the piercing needle. • There is variability in the single-serve pack manufacturing process which causes some types of single-serve packs to be weaker at the seams. Try a different brand. 10 840239403 ENv02.indd 10 1/16/15 11:27 AM
10
Troubleshooting
(cont.)
PROBLEM
PROBABLE CAUSE/SOLUTION
Coffee not dispensing.
• Piercing needle is clogged with coffee grounds. Turn unit off; unplug. Allow unit to cool
completely. To remove any built-up coffee grounds, insert end of bent paper clip into eye and up
into the piercing needle.
Failed foil seal.
• There is variability in the single-serve pack manufacturing process which causes some types of
single-serve packs to be weaker at the seams. Try a different brand.
840239403 ENv02.indd 10
840239403 ENv02.indd
10
1/16/15 11:27 AM
1/16/15
11:27 AM