Hayward HCP Pump HCP Series LITCPOMA10 - Page 8
Dimensions
View all Hayward HCP Pump manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
DIMENSIONS Total Dynamic Head (Ft) 3. Dimensions FIGURE 3.1 A 17.5" 4" IPS UNION Model HP (A) Inch HCP55 5.5 34.2 HCP75 7.5 36.0 HCP100 10.0 37.2 HCP125 12.5 37.2 23" 4" IPS UNION 16.8" 3.8" 1.5" 4.3" 15.2" 14" 21.5" 10.5" .4" 5.7" Performance Data 100 90 80 70 60 50 40 30 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 F low (G P M ) PERFORMANCE - PERFORMANCE - PERFORMANCE - PERFORMANCE - HCP55 HCP75 HCP100 HCP125 All motors: Certified to UL 1004, IP 55 protection, insulation class F. 60 hz., 3.550 R.P.M. Head Loss in Ft - HCP Single Speed Pumps PERFORMACE - PERFORMACE - PERFORMACE - PERFORMACE - GPM HCP55 HCP75 HCP100 HCP125 0 77.4 83.2 87.78 95.9 50 73.3 80.1 85 94.64 100 69.5 76.8 82.8 92.44 150 66.2 73.6 80 89.42 200 62.4 70.8 77.1 85.9 250 58.5 68 74 82.43 300 53.9 65 71 78.8 350 48.3 61.4 67.7 75.5 400 41.2 57.9 64.2 72 450 32 53.2 60.7 68 500 48 56.7 63.2 550 41.5 51.9 58 600 33 45.33 53.2 650 38 47.4 700 FIGURE 3.2 - ELECTRICAL SPECIFICATIONS: Commercial Pump Ordering Information Model No. HCP55 HCP75 HCP100 HCP125 Horse-power 5.5 hp 7.5 hp 10.0 hp 12.5 hp Voltage 230/460 230/460 230/460 230/460 Phase 3 3 3 3 Amps 14.6/7.3 21/10.5 26.1/13 31.6/15.8 Dimensions 35.00" 35.98" 37.16" 38.74" Shipping Weight (lbs) 101 132 154 165 8