Hayward Max-Flo VS™ Max-Flo VS™ Manual - Page 22

Warranty - max flo vs error 64

Page 22 highlights

11.2. Error Codes In the case that an internal failure has been detected the pump will turn the motor off and display an error code listed below. If more than one error has been detected the screen will flash between the errors. The cause of the error should be investigated and resolved before continuing normal operation of the pump. When the issue has been resolved, press the RUN / STOP key to clear the error message. Screen Buttons Used Comments Error Number Detected Code: 01 02 10 20 64 97 98 12. Warranty Indications: Undervoltage on DC-Link Overvoltage on DC-Link Current Measurement Fails Permanently Overload During Start Up Process Short Circuit Failure Multiple Errors at the Same Time, i.e. Undervoltage and Overload Error Communication Failure From controller Page 22 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max-Flo VS Pump IS2300VSP Rev C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 22 of 24
Max-Flo VS Pump
IS2300VSP
Rev C
11.2.
Error Codes
In the case that an internal failure has been detected the pump will turn the motor off and display an error code listed
below. If more than one error has been detected the screen will flash between the errors.
The cause of the error
should be investigated and resolved before continuing normal operation of the pump.
When the issue has been
resolved, press the RUN / STOP key to clear the error message.
Screen
Buttons Used
Comments

Error Number Detected
Code:
Indications:
01
Undervoltage on DC-Link
02
Overvoltage on DC-Link
10
Current Measurement Fails Permanently
20
Overload During Start Up Process
64
Short Circuit Failure
97
Multiple Errors at the Same Time, i.e. Undervoltage and Overload Error
98
Communication Failure From controller
12.
Warranty