Hayward Pro Logic® Model: PL-P-4 Operation - Page 35

pH Timeout - Check Feeder

Page 35 highlights

• Low Volts -- If the chlorinator cell voltage is too low. • No Cell Power -- If no chlorinator cell power is detected on the printed circuit board. • Check Flow Switch -- If the flow switch input is invalid. • Cell Power Error -- If a chlorinator cell power error is detected on the printed circuit board. • Cell Missing -- If the chlorinator is enabled but no cell is detected. • Filter VSP Comm Error-- If variable speed is selected for the Filter and the Hayward VSP interface is not responding. • Filter VSP Drive Comm Error -- If variable speed is selected for the Filter and the Hayward VSP drive controller is not responding. • Filter VSP Err: x -- If variable speed is selected for the Filter and the Hayward VSP is indicating and error. x is the same decimal error displayed by the VSP itself. • Aux1 VSPComm Error -- If variable speed is selected for theAux1 relay type and the Hayward VSP interface is not responding. • Aux1 VSP Drive Comm Error -- If variable speed is selected for the Aux1 relay type and the Hayward VSP drive controller is not responding. • Aux1 VSP Err: x -- If variable speed is selected for the Aux1 relay type and the Hayward VSP is indicating and error. x is the same decimal error displayed by the VSP itself. For Pool Filter and Aux using Gen2 EcoStar Variable Speed Pumps only: • Main Voltage is too low • Main Voltage is too high • Remote Stop was pressed (Press "+" to restart) • Prime Failed (Press "+" to restart) • Failed to start (Press "+" to restart) • Pump has stalled (Press "+" to restart) • SVRS tripped (Press "+" to restart) • Drive failure (see Pump Display) • CSM Comm Error: -- If Chemistry Sensing is enabled and the Chemistry Sense Module (CSM) is not responding. • pH Probe Error -- If the CSM indicates that there is a problem with the pH probe. • pH Low - Check Feeder -- If a pH level of 6.9 or less is detected, check the feeder for proper operation • pH High - Check Feeder -- If a pH level of 8.1 or higher is detected, check the chemical supply and the feeder for proper operation • pH Timeout - Check Feeder -- If the unit has been dispensing pH for more than the selected timeout without reaching the desired level. Check the chemical supply and the feeder. If both are OK, the timeout may need to be increased. Press the "+" button to reset the alarm and resume dispensing. • pH Calibration Error -- When using the pH Calibration Wizard and the entered test result was different from the measured pH level by ± 1.0 or more. The pH probe may need to be cleaned or replaced. • ORP Probe Error -- If the CSM indicates that there is a problem with the ORP probe. • ORP Low - Check Chlor -- If an ORP level of 350mV or less is detected. Check the chlorinator for proper operation. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

32
Low Volts
-- If the chlorinator cell voltage is too low.
No Cell Power
-- If no chlorinator cell power is detected on the printed circuit board.
Check Flow Switch
-- If the flow switch input is invalid.
Cell Power Error
-- If a chlorinator cell power error is detected on the printed circuit board.
Cell Missing
-- If the chlorinator is enabled but no cell is detected.
Filter VSP Comm Error
-- If variable speed is selected for the Filter and the Hayward VSP interface
is not responding.
Filter VSP Drive Comm Error
-- If variable speed is selected for the Filter and the Hayward VSP
drive controller is not responding.
Filter VSP Err: x
-- If variable speed is selected for the Filter and the Hayward VSP is indicating and
error.
x is the same decimal error displayed by the VSP itself.
Aux1 VSP Comm Error
-- If variable speed is selected for the Aux1 relay type and the Hayward VSP
interface is not responding.
Aux1 VSP Drive Comm Error
-- If variable speed is selected for the Aux1 relay type and the
Hayward VSP drive controller is not responding.
Aux1 VSP Err: x
-- If variable speed is selected for the Aux1 relay type and the Hayward VSP is
indicating and error.
x is the same decimal error displayed by the VSP itself.
For Pool Filter and Aux using Gen2 EcoStar Variable Speed Pumps only:
Main Voltage is too low
Main Voltage is too high
Remote Stop was pressed (Press “+” to restart)
Prime Failed (Press “+” to restart)
Failed to start (Press “+” to restart)
Pump has stalled (Press “+” to restart)
SVRS tripped (Press “+” to restart)
Drive failure (see Pump Display)
CSM Comm Error:
-- If Chemistry Sensing is enabled and the Chemistry Sense Module (CSM) is
not responding.
pH Probe Error
-- If the CSM indicates that there is a problem with the pH probe.
pH Low - Check Feeder
-- If a pH level of 6.9 or less is detected, check the feeder for proper
operation
pH High - Check Feeder
-- If a pH level of 8.1 or higher is detected, check the chemical supply and
the feeder for proper operation
pH Timeout - Check Feeder
-- If the unit has been dispensing pH for more than the selected timeout
without reaching the desired level. Check the chemical supply and the feeder.
If both are OK, the
timeout may need to be increased.
Press the “+” button to reset the alarm and resume dispensing.
pH Calibration Error
-- When using the pH Calibration Wizard and the entered test result was
different from the measured pH level by ± 1.0 or more.
The pH probe may need to be cleaned or
replaced.
ORP Probe Error
-- If the CSM indicates that there is a problem with the ORP probe.
ORP Low - Check Chlor
-- If an ORP level of 350mV or less is detected. Check the chlorinator for
proper operation.