TECHNICAL SPECIFICATIONS Enclosure 7.25" x 8.25" x 2.63" glass-filled polycarbonate Interface UV-protected Lexan membrane switch Certifications UL94-5V (UL746 C5), NEMA type 1, 4, 4X, 6, 12, 13 NSF / ANSI Standard 50 Display Light-emitting diode Keys Embossed with stainless tactile domes Display Range pH 1.0-9.9 / ORP 5-995 mV Flow Cell Injection-molded machined acrylic* Backboard CNC machined and beveled PVC Flow Sensor Float-style magnetic with embedded reed switch* Power Input USA - 15 Amp, 120 VAC 60 Hz Intl. - 10 Amp, 230 VAC 50/60 Hz** Output Power pH / ORP relays - 4 Amp, 120/230 VAC Auxiliary Relay AUX pH / ORP relays - dry contacts - 4 Amp Communications RS232 serial interface Remote alarm - dry contact relay - 4 Amp Safety Systems pH low and high alarms ORP low and high alarms pH priority feed Supplemental feed modes pH and ORP overfeed timeout Flow alarms Set Point Range Control Accuracy Alarm Ranges Mode Selections pH 7.0-8.0 ORP 200-995 mV pH +/- 0.1 pH ORP +/- 5.0 mV pH - low 6.0 pH / high 9.0 pH ORP - low 200 mV / high 995 mV pH automatic / off / manual for 30 minute direct feed ORP automatic / off / manual for 30 minute direct feed pH feed - acid or base ORP mode - auto / set pH mode - auto / set / calibrate Optional Equipment RS232 serial interface cable 2 - lead low-voltage cable Thermal printer / data logger CO2 feed systems (pH control) Inputs CAT Professional Series pH sensor CAT Professional Series ORP sensor CAT magnetic rotary - flow sensor CAT magnetic float - flow sensor Thermal printer / data logger Outputs pH acid feed pH base feed ORP sanitizer feed Chlorine generation interface Remote alarm Data output through RS232 Warranty 5-year limited warranty on controller 2-year warranty on sensors PART NUMBERS PART NUMBERS CAT2000 DESCRIPTION CAT 2000® Standard Package* CAT-PP2000 CAT 2000 Professional Package*** CARTON QTY WEIGHT 1 15 lbs. 1 20 lbs. DIMENSIONS (CAT 2000 Professional Package) A 21" B 16" C 8.25" D 4.5" E 8" F 16" G 7" H 3.125" OPTIONAL EQUIPMENT PART NUMBER HCSC110 DESCRIPTION Saline C® 11.0 Salt Chlorine Generator CARTON QTY WEIGHT 1 50 lbs. HCSC60 Saline C® 6.0 Salt Chlorine Generator 1 AQL-CHEM4-ACID Complete pH Chemical Feed System with 15 Gallon Tank and Containment Tray 1 AQL-CHEM4-CHLOR Complete Cl Chemical Feed System with 15 Gallon Tank and Containment Tray 1 25 lbs. 24 lbs. 24 lbs. AC004 Standard CO2 System 1 7 lbs. pH/Cl CHEMICAL FEED SYSTEMS CO2 FEEDER SALINE C® SYSTEM *Standard Package includes Molded Flow Cell and Float-Style Flow Sensor **For international version and part number information, please contact your local Hayward® sales representative ***Professional Package includes Machined Acrylic Flow Cell and Rotary Flow Sensor » haywardcommercialpool.com » (301) 838-4001 CAT 2000 Controllers are listed by: Hayward, Hayward & Design, the H logo, CAT Controllers, CAT 2000 and Saline C are registered trademarks of Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated with or endorsed by those third parties. © 2018 Hayward Industries, Inc. SPECCC2000A18

  • 1
  • 2

TECHNICAL SPECIFICATIONS
Enclosure
7.25" x 8.25" x 2.63" glass-filled
polycarbonate
Interface
UV-protected Lexan membrane switch
Certifications
UL94-5V (UL746 C5),
NEMA type 1, 4, 4X, 6, 12, 13
NSF / ANSI Standard 50
Display
Light-emitting diode
Keys
Embossed with stainless tactile domes
Display Range
pH 1.0-9.9 / ORP 5-995 mV
Flow Cell
Injection-molded machined acrylic*
Backboard
CNC machined and beveled PVC
Flow Sensor
Float-style magnetic with embedded
reed switch*
Power Input
USA - 15 Amp, 120 VAC 60 Hz
Intl. - 10 Amp, 230 VAC 50/60 Hz**
Output Power
pH / ORP relays - 4 Amp, 120/230 VAC
Auxiliary Relay
AUX pH / ORP relays - dry contacts - 4 Amp
Communications
RS232 serial interface
Remote alarm - dry contact relay - 4 Amp
Safety Systems
pH low and high alarms
ORP low and high alarms
pH priority feed
Supplemental feed modes
pH and ORP overfeed timeout
Flow alarms
Set Point Range
pH 7.0-8.0
ORP 200-995 mV
Control Accuracy
pH +/- 0.1 pH
ORP +/- 5.0 mV
Alarm Ranges
pH - low 6.0 pH / high 9.0 pH
ORP - low 200 mV / high 995 mV
Mode Selections
pH automatic / off / manual for 30 minute
direct feed
ORP automatic / off / manual for 30
minute direct feed
pH feed - acid or base
ORP mode - auto / set
pH mode - auto / set / calibrate
Optional Equipment
RS232 serial interface cable
2 - lead low-voltage cable
Thermal printer / data logger
CO
2
feed systems (pH control)
Inputs
CAT Professional Series pH sensor
CAT Professional Series ORP sensor
CAT magnetic rotary - flow sensor
CAT magnetic float - flow sensor
Thermal printer / data logger
Outputs
pH acid feed
pH base feed
ORP sanitizer feed
Chlorine generation interface
Remote alarm
Data output through RS232
Warranty
5-year limited warranty on controller
2-year warranty on sensors
OPTIONAL EQUIPMENT
PART NUMBER
DESCRIPTION
CARTON
QTY
WEIGHT
HCSC110
Saline C
®
11.0 Salt Chlorine Generator
1
50 lbs.
HCSC60
Saline C
®
6.0 Salt Chlorine Generator
1
25 lbs.
AQL-CHEM4-ACID
Complete pH Chemical Feed System with
15 Gallon Tank and Containment Tray
1
24 lbs.
AQL-CHEM4-CHLOR
Complete Cl Chemical Feed System with
15 Gallon Tank and Containment Tray
1
24 lbs.
AC004
Standard CO
2
System
1
7 lbs.
PART NUMBERS
PART NUMBERS
DESCRIPTION
CARTON
QTY
WEIGHT
CAT2000
CAT 2000
®
Standard Package*
1
15 lbs.
CAT-PP2000
CAT 2000 Professional Package***
1
20 lbs.
»
haywardcommercialpool.com
»
(301) 838-4001
Hayward, Hayward & Design, the H logo, CAT Controllers, CAT 2000 and Saline C are registered trademarks of Hayward
Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way
affiliated with or endorsed by those third parties. © 2018 Hayward Industries, Inc.
SPECCC2000A18
DIMENSIONS
(CAT 2000
Professional
Package)
A
21"
B
16"
C
8.25"
D
4.5"
E
8"
F
16"
G
7"
H
3.125"
CAT 2000 Controllers are listed by:
*Standard Package includes Molded Flow Cell and Float-Style Flow Sensor
**For international version and part number information, please contact your local Hayward
®
sales representative
***Professional Package includes Machined Acrylic Flow Cell and Rotary Flow Sensor