Hayward Star-Clear Models: C1200 C12002 C12002S C17502 C17502S C751 C751 - Page 2

Parts

Page 2 highlights

4. Connect the pool suction plumbing between the skimmer, pool outlet, etc. and the pump. 5. Install the pool return plumbing. 6. If pressure gauge is not installed, apply Teflon tape to the gauge threads, and carefully screw the gauge into the threaded hole in the filter head. 7. A filter drain plug is furnished with each filter and is all that is needed for complete filter draining. A manual air relief valve is furnished to aid in bleeding off unwanted air when starting the filter. The auto air relief provides air removal during operation. 8. All electrical connections should be made in accordance with local codes. 9. Check for joint leaks before operating. 10. Refer to pump instruction booklet for pump information. MODEL NO. C751 C900 C1200 C7512 C9002(S) C12002(S) C17502(S) EFFECTIVE FILTRATION AREA FT' M' 75 7.0 90 8.4 120 11.2 DESIGN FLOW RATE RESIDENTIAL PUBLIC PRESSURE LOSS AT DESIGN FLOW RATE RESIDENTIAL PUBLIC GPM LPM 75 284 90 341 120 i 454 GPM 29 34 45 LPM PSI 110 1.80 129 3.60 170 i 7.20 BAR 0.12 0.24 0.48 PSI 0.00 0.20 0.50 BAR 0.00 0.01 0.03 75 7.0 75 284 28 106 0.25 0.02 0.00 0.00 90 8.4 90 341 34 129 0.50 0.03 0.00 0.00 120 11.2 120 454 45 170 1.00 0.07 0.00 0.00 175 16.3 120 454 60 227 1.00 0.07 0.10 0.00 MAXIMUM WORKING PRESSURE PSI BAR 50 3.45 50 3.45 50 3.45 50 3.45 50 3.45 50 3.45 50 3.45 REQUIRED CLEARANCE SIDE ABOVE INCH CM INCH CM 18 46 19 48 18 46 19 48 18 46 25 64 18 46 19 48 18 46 19 48 18 46 25 64 18 46 30 76 PARTS Models C751, C7512, C900, C9002(S) and C1200, C12002(S) and C17502(S) Filters REF. NO. PART NO. la CX900G CX1750C 2 CX900H 3 CX900W 4 CX900J 5 CX900D 6a CX900B 6b CX1200B 6c CX1750B 7 C-900F 8a CX900AA 8b CX900AA2 9 ECX2709 10a CX760RE 10b CX900RE 10c CX1200RE 10d CX1750RE 11a CX800Z2 11b CX1100Z2 11c CX1750RE 12a CX800Z4 12b CX1100Z4 12c CX1750Z4 13 CX250Z14 14 SPX605Z2 15 CX900K 16 ECX1322A DESCRIPTION NO. REO'D. Locking Knob 1 Locking Knob 0 -Ring ) Washer 2 E-Ring 1 Guide Cone Filter Head w/Directional Vent Valve (C900) 1 Filter Head w/Directional Vent Valve (C1200) 1 Filter Head w/Directional Vent Valve (C1750) 1 Filter Head 0-Ring 1 Filter Body-1-1/2" FIP 1 Filter Body-2' FIP 1 Pressure Gauge 1 Cartridge Element (C751. C7512) Cartridge Element (0900) Cartridge Element (01200) 1 Cartridge Element (C1750) 1 Tie Rod (C900) 1 Tie Rod (C1200) 1 Tie Rod (C1750) 1 Auto Air Relief Tube (C900) 1 Auto Air Relief Tube (C1200) 1 Auto Air Relief Tube (C1750) 1 1/2" Drain Plug I 1 Drain Plug 0-Ring 1 2" PVC Socket Connector, Set of 2 (Not Shown) 2 Directional Vent Valve w/O-Ring 1 to0I1011att is CED-c:= a 12 b - d Oa b 11 14 13

  • 1
  • 2
  • 3
  • 4

4.
Connect
the
pool
suction
plumbing
between
the
skimmer,
pool
outlet,
etc.
and
the
pump.
5.
Install
the
pool
return
plumbing.
6.
If
pressure
gauge
is
not
installed,
apply
Teflon
tape
to
the
gauge
threads,
and
carefully
screw
the
gauge
into
the
threaded
hole
in
the
filter
head.
7.
A
fi
lter
drain
plug
is
furnished
with
each
filter
and
is
all
that
is
needed
for
complete
filter
draining.
A
manual
air
relief
valve
is
furnished
to
aid
in
bleeding
off
unwanted
air
when
starting
the
filter.
The
auto
air
relief
provides
air
removal
during
operation.
8.
All
electrical
connections
should
be
made
in
accordance
with
local
codes.
9.
Check
for
joint
leaks
before
operating.
10.
Refer
to
pump
instruction
booklet
for
pump
information.
MODEL
NO.
EFFECTIVE
FILTRATION
AREA
DESIGN
FLOW
RATE
PRESSURE
LOSS
AT
DESIGN
FLOW
RATE
MAXIMUM
WORKING
PRESSURE
REQUIRED
CLEARANCE
RESIDENTIAL
PUBLIC
RESIDENTIAL
PUBLIC
SIDE
ABOVE
FT'
M'
GPM
LPM
GPM
LPM
PSI
BAR
PSI
BAR
PSI
BAR
INCH
CM
INCH
CM
C751
75
7.0
75
284
29
110
1.80
0.12
0.00
0.00
50
3.45
18
46
19
48
C900
90
8.4
90
341
34
129
3.60
0.24
0.20
0.01
50
3.45
18
46
19
48
C1200
120
11.2
120
i
454
45
170
i
7.20
0.48
0.50
0.03
50
3.45
18
46
25
64
C7512
75
7.0
75
284
28
106
0.25
0.02
0.00
0.00
50
3.45
18
46
19
48
C9002(S)
90
8.4
90
341
34
129
0.50
0.03
0.00
0.00
50
3.45
18
46
19
48
C12002(S)
120
11.2
120
454
45
170
1.00
0.07
0.00
0.00
50
3.45
18
46
25
64
C17502(S)
175
16.3
120
454
60
227
1.00
0.07
0.10
0.00
50
3.45
18
46
30
76
PARTS
Models
C751,
C7512,
C900,
C9002(S)
and
C1200,
C12002(S)
and
C17502(S)
Filters
REF.
NO.
PART
NO.
DESCRIPTION
NO.
REO'D.
la
CX900G
Locking
Knob
1
CX1750C
Locking
Knob
2
CX900H
0
-Ring
)
3
CX900W
Washer
2
4
CX900J
E
-Ring
1
5
CX900D
Guide
Cone
6a
CX900B
Filter
Head
w/Directional
Vent
Valve
(C900)
1
6b
CX1200B
Filter
Head
w/Directional
Vent
Valve
(C1200)
1
6c
CX1750B
Filter
Head
w/Directional
Vent
Valve
(C1750)
1
7
C
-900F
Filter
Head
0
-Ring
1
8a
CX900AA
Filter
Body
-1-1/2"
FIP
1
8b
CX900AA2
Filter
Body
-2'
FIP
1
9
ECX2709
Pressure
Gauge
1
10a
CX760RE
Cartridge
Element
(C751.
C7512)
10b
CX900RE
Cartridge
Element
(0900)
10c
CX1200RE
Cartridge
Element
(01200)
1
10d
CX1750RE
Cartridge
Element
(C1750)
1
11a
CX800Z2
Tie
Rod
(C900)
1
11b
CX1100Z2
Tie
Rod
(C1200)
1
11c
CX1750RE
Tie
Rod
(C1750)
1
12a
CX800Z4
Auto
Air
Relief
Tube
(C900)
1
12b
CX1100Z4
Auto
Air
Relief
Tube
(C1200)
1
12c
CX1750Z4
Auto
Air
Relief
Tube
(C1750)
1
13
CX250Z14
1/2"
Drain
Plug
I
1
14
SPX605Z2
Drain
Plug
0
-Ring
1
15
CX900K
2"
PVC
Socket
Connector,
Set
of
2
(Not
Shown)
2
16
ECX1322A
Directional
Vent
Valve
w/O-Ring
1
is
a
12
b
Oa
b
to0I1011att
CED--
c:=
14