092666 RevB TurboCell® S3 (New Menu Setting May Be Required) TurboCell S3 chlorinator cells can be used to replace older TurboCell models but changes to the chlorinator may be required. Refer to the table below to cross reference TurboCell S3 models to older models. Use this cross referenced model when configuring the chlorinator. If your chlorinator does not offer the cross referenced selection, do not use the TurboCell S3. Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shutdown. TurboCell S3 model TCELLS340, TCELLS340W TCELLS325, TCELLS325W TCELLS318, TCELLS318W TCELLS315, TCELLS315W TCELLS340X25 Choose this selection in the chlorinator's menu if your model is not offered t-15 or T-CELL-15 t-9 or T-CELL-9 t-5 or T-CELL-5 t-3 or T-CELL-3 t-15 or T-CELL-15 Pool (Gallons) Pool (Liters) 40,000 25,000 18,000 15,000 40,000 151,400 94,600 68,100 56,700 151,400 CONFIGURATION is necessary with the following models: • AQR (AquaRite® - all 2009 or later) - firmware version 1.5 or later • AQR-PRO (AquaRite Pro) • PL-P-4 (ProLogic® P4), AQ-LOGIC-P-4 (AquaLogic P4) • PL-PS-x (ProLogic PS), AQ-LOGIC-PS-x (AquaLogic PS) • OmniLogic®, OmniPL®, S3 Omni • AQRS3 The following chlorinators are only compatible with TCELLS340, TCELLS340X25 and TCELLS340W models • AQ-RITE (AquaRite - 2008 and earlier) - firmware earlier than version 1.5, no configuration necessary • AQ-RITE-XL (AquaRite XL), no configuration necessary For AQR: 1. Slide the Main Switch to the "Auto" position. 2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the factory default). 3. To change cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto". 4. Push the Diagnostic button to exit. For AQR-PRO: 1. Access the Settings Menu by pushing the "Settings" button. 2. Push ">" until Chlor. Config is displayed, then push "+". 3. Push ">" repeatedly until "Cell Type" is displayed. 4. Push "+" or "-" until desired model is displayed. 5. Exit Settings Menu by pushing the "Info" button. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
TurboCell
S3
(New Menu Setting May Be Required)
TurboCell S3 chlorinator cells can be used to replace older TurboCell models but changes to the chlorinator may be required. Refer
to the table below to cross reference TurboCell S3 models to older models. Use this cross referenced model when configuring the
chlorinator. If your chlorinator does not offer the cross referenced selection, do not use the TurboCell S3. Incorrect configuration will
cause inaccurate salt readings, improper operation, and possible system shutdown.
TurboCell S3 model
Choose this selection in the chlorinator’s
menu if your model is not offered
Pool (Gallons)
Pool (Liters)
TCELLS340, TCELLS340W
t-15 or T-CELL-15
40,000
151,400
TCELLS325, TCELLS325W
t-9 or T-CELL-9
25,000
94,600
TCELLS318, TCELLS318W
t-5 or T-CELL-5
18,000
68,100
TCELLS315, TCELLS315W
t-3 or T-CELL-3
15,000
56,700
TCELLS340X25
t-15 or T-CELL-15
40,000
151,400
CONFIGURATION is necessary with the following models:
AQR (AquaRite
- all 2009 or later) - firmware version 1.5 or later
AQR-PRO (AquaRite Pro)
PL-P-4 (ProLogic
P4), AQ-LOGIC-P-4 (AquaLogic P4)
PL-PS-x (ProLogic PS), AQ-LOGIC-PS-x (AquaLogic PS)
OmniLogic ,
OmniPL,
S3 Omni
AQRS3
The following chlorinators are only compatible with TCELLS340, TCELLS340X25 and TCELLS340W models
AQ-RITE (AquaRite - 2008 and earlier) - firmware earlier than version 1.5, no configuration necessary
AQ-RITE-XL (AquaRite XL), no configuration necessary
For AQR:
1.
Slide the Main Switch to the “Auto” position.
2.
Push the Diagnostic button repeatedly until “t-xx” appears on the display (“t-15” is the factory default).
3.
To change cell type, slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”.
4.
Push the Diagnostic button to exit.
For AQR-PRO:
1.
Access the Settings Menu by pushing the “Settings” button.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
Push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until desired model is displayed.
5.
Exit Settings Menu by pushing the “Info” button.
092666 RevB
®
®
®
®
®